Table 59. POST Progress Code LED Example 
Scenario: BIOS sent value of 95h to POST Progress Code LED 
LEDs 
Red 
Green 
Red 
Green 
Red 
Green 
Red 
Green 
95h 
1 0 0 1 0 0 1 1 
Result Red 
Green 
Off 
Amber 
 
(8) - Hi Bit – as 
viewed by looking into 
the system from the 
back 
(4) 
(2) 
(1) Low Bit – as 
viewed by looking into 
the system from the 
back 
 
Note: When comparing a diagnostic LED color string from the baseboard to those listed in the 
diagnostic LED decoder in the following tables, the LEDs on the baseboard should be 
referenced when viewed by looking into the system from the back. Reading the LEDs from left 
to right, the Hi bit is located on the left. 
6.41.2 
POST Error Codes and Messages 
The following table defines POST error codes and their associated messages. The BIOS 
prompts the user to press a key in case of serious errors. Some of the error messages are 
preceded by the string "Error” to highlight the fact that the system might be malfunctioning. All 
POST errors and warnings are logged in the System Event Log, unless the System Event Log is 
full. 
Table 60. Standard POST Error Messages and Codes 
Error Code 
Error Message 
Pause on Boot 
100 
Timer Channel 2 Error 
Yes 
101 
Master Interrupt Controller 
Yes 
102 
Slave Interrupt Controller 
Yes 
103 
CMOS Battery Failure 
Yes 
104 
CMOS Options not Set 
Yes 
105 
CMOS Checksum Failure 
Yes 
106 
CMOS Display Error 
Yes 
107 
Insert Key Pressed 
Yes 
108 
Keyboard Locked Message 
Yes 
109 
Keyboard Stuck Key 
Yes 
10A 
Keyboard Interface Error 
Yes 
10B 
System Memory Size Error 
Yes 
10E 
External Cache Failure 
Yes 
110 
Floppy Controller Error 
Yes 
111 
Floppy A: Error 
Yes 
113 
Hard disk 0 Error 
Yes 
114 
Hard disk 1 Error 
Yes 
115 
Hard disk 2 Error 