Emerson 600 Benutzerhandbuch

Seite von 3
1
F O R M
Tenso-set™ Series 600  
Auto-Tensioning Motor Base  
Installation and Maintenance Manual
9884E
June 2014
Emerson Industrial Automation
7120 New Buffington Road
Florence, KY 41042
Application Engineering: 800 626 2093
www.PowerTransmissionSolutions.com
CAUTION
•  Periodic inspections should be performed. Failure to perform proper maintenance 
can result in premature product failure and personal injury.
•  All electrical work should be performed by qualified personnel and compliant with 
local and national electrical codes.
WARNING
•  Read and follow all instructions carefully.
•  Disconnect and lock-out power before installation and maintenance.   
Working on or near energized equipment can result in severe injury or death.
•  Avoid contact with energized circuits or rotating parts.
•  Be sure shaft key is fully captive before unit is energized.
•  Do not operate equipment without guards in place.  Exposed equipment can 
result in severe injury or death.
Browning, Emerson and Emerson Industrial Automation are trademarks of Emerson 
Electric Co. or one of its affiliated companies. 
©2014 Emerson Power Transmission Corp., All Rights Reserved.
MCIM14006E  • Form 9884E • Printed in USA
Motor Carriage
Tension Nut
Mounting Brackets
Tension Rod
Carriage Rods
Installation Instructions
1.  Mount the motor on the motor base using the recommended 
grade 5 bolts and torques listed in table 1.
Table 1
Motor Base
Bolt Size
Torque (Grade 5 plated )
BSAMBN601
5/16-18
13 Lb-Ft
BSAMBN605
3/8-16
23 Lb-Ft
BSAMBN607
3/8-16
23 Lb-Ft
BSAMBN613
3/8-16
23 Lb-Ft
BSAMBN621
1/2-13
57 Lb-Ft
BSAMBN623
1/2-13
57 Lb-Ft
2.  Mount the sheaves on the Driver and Driven Shafts.