Lowrance electronic X515C DF Benutzerhandbuch

Seite von 128
109 
1. Press 
MENU| MENU
, use 
↓ ↑  to select 
NMEA
 
2000
 and press 
ENT
2. Highlight 
B
US 
S
ETUP
 and press 
ENT
, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page.    
3. Select the desired EP-15 Fluid Level and press 
ENT
4. Press 
↓ to select 
C
ALIBRATE
 and press 
ENT
. The Device Calibration 
menu will appear. 
5. Highlight 
N
UM 
P
TS
, press 
ENT
 and select 
5
. Press 
ENT
6. 
Make sure your tank is empty, then
 
highlight
  F
LUID 
L
EVEL
 
and press
 
ENT
.
 
Select
 E
MPTY LEVEL 
and press
 ENT.  
7. 
Select
  C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Empty Level Calibration Completed. Press 
ENT
.
 
8. 
Add 1 quarter tank of fuel, highlight
 F
LUID 
L
EVEL
 
and press
 ENT
.
 
Select
 
1
 
Q
TR 
L
EVEL 
and press ENT.  
9.  Select  C
ALIBRATE
 and press ENT
. The following message will appear: 
Qtr Level Calibration Completed. Press 
ENT
10. Add another quarter tank of fuel, which should raise the fuel level 
to half a tank. Highlight
 F
LUID 
L
EVEL
 
and press
 ENT
.
 
Select
 H
ALF LEVEL 
and 
press
 ENT
11. 
Highlight
  C
ALIBRATE
 
and press
 ENT
. The following message will ap-
pear: Half Level Calibration Completed. Press 
ENT
12. Add another quarter tank of fuel, which should raise the fuel level 
to 3 quarters of a tank. Highlight
 F
LUID 
L
EVEL
 
and press
 ENT
.
 
Select
 3
 
Q
TR 
L
EVEL 
and press
 ENT
13. 
Select
 C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Qtr Level Calibration Completed. Press 
ENT
14. Top off the tank, highlight
  F
LUID 
L
EVEL
 
and press
  ENT
.
 
Select
  F
ULL 
L
EVEL 
and press
 ENT
15. 
Select
  C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Full Level Calibration Completed. Press 
ENT
, then press 
EXIT
 repeat-
edly to get back to the main display. 
Fuel Flow Calibration in a Suzuki Engine Interface 
The default calibration for the Suzuki Engine Interface is adequate in 
most cases, but if Fuel Used readings are off by more than 3 percent, 
calibration is recommended. 
To check engine interface accuracy: 
Select Fuel Used to be shown as Overlay Data on your unit's main dis-
play. Refer to the Overlay Data segment of this manual for instructions 
on how to select Fuel Used data as Overlay Data.