BURNER FLAME PATTERN
Figure 53 shows a correct burner flame pattern. 
Figure 54 shows an incorrect burner flame pattern. 
The incorrect burner flame pattern shows sporadic, 
irregular flame tipping. The flame should not be 
dark or have an orange/reddish tinge.
Note:
  When using the fireplace the first time, the 
flame will be orange for approximately one hour 
until the log cures. 
If burner flame pattern is incorrect, as shown in 
Figure 54
•  turn fireplace off (see To Turn Off Gas to Appli-
ance, page 23 for Thermostat-Controlled Mod-
els or page 25 for Remote-Ready Models)
•  see Troubleshooting, page 30
Figure 53 - Correct Burner Flame Pattern
Figure 54 - Incorrect Burner Flame 
Pattern 
CLEANING AND 
MAINTENANCE
 WARNING: Turn off fireplace 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control  areas,  burner,  and  cir-
culating  air  passageways  of 
fireplace  clean.  Inspect  these 
areas  of  fireplace  before  each 
use.  Have  fireplace  inspected 
yearly  by  a  qualified  service 
person.  Fireplace  may  need 
more frequent cleaning due to 
excessive  lint  from  carpeting, 
pet hair, bedding material, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
BURNER INJECTOR HOLDER AND 
PILOT AIR INLET HOLE
The  primary  air  inlet  holes  allow  the  proper 
amount of air to mix with the gas. This provides 
a clean burning flame. Keep these holes clear of 
dust, dirt, lint, and pet hair. Clean these air inlet 
holes prior to each heating season. Blocked air 
holes will create soot. We recommend that you 
clean the unit every three months during operation 
and have fireplace inspected yearly by a qualified 
service person.
We  also  recommend  that  you  keep  the  burner 
tube and pilot assembly clean and free of dust and 
dirt. To clean these parts we recommend using 
compressed air no greater than 30 PSI. Your local 
computer store, hardware store, or home center 
may carry compressed air in a can. You can use a 
vacuum cleaner in the blow position. If using com-
pressed air in a can, please follow the directions on 
the can. If you donʼt follow directions on the can, 
you could damage the pilot assembly.
1.  Shut off the unit, including the pilot. Allow 
the unit to cool for at least thirty minutes.
2.  Inspect burner, pilot, and primary air inlet 
holes on injector holder for dust and dirt (see 
Figure 55).
3.  Blow air through the ports/slots and holes in 
the burner.
4.  Check the injector holder located at the end 
of the burner tube again. Remove any large 
particles of dust, dirt, lint, or pet hair with a 
soft cloth or vacuum cleaner nozzle.
5.  Blow air into the primary air holes on the 
injector holder.
6.  In case any large clumps of dust have now been 
pushed into the burner repeat steps 3 and 4.
INSPECTING BURNERS
CONTINUED
Figure 55 - Injector Holder On Outlet 
Burner Tube
Burner 
Tube
Injector 
Holder
Primary Air 
Inlet Holes