Desa VSGF36PRA Benutzerhandbuch

Seite von 40
www.desatech.com
116746-01A
26
WIRING DIAGRAM
Note:
 For proper operation of optional accessories, 
the wires from the thermopile to the control must 
be connected exactly as shown.
Thermopile
SPECIFICATIONS
Models VSGF36NTA and VSGF36NRA
Btu (Variable) 
33,000/21,500
Type Gas  
Natural Gas
Ignition 
Piezo
Pressure Manifold  
3.5" W.C.
Inlet Gas Pressure (in. of water)
  Maximum 
10.5" 
  Minimum* 
5"
Shipping Weight  
120 lbs.
* For input adjustment
Models VSGF36PTA and VSGF36PRA
Btu (Variable) 
33,000/21,500
Type Gas  
Propane/LP
Ignition 
Piezo
Pressure Manifold  
7.9" W.C.
Inlet Gas Pressure (in. of water)
  Maximum 
13" 
  Minimum* 
11"
Shipping Weight  
120 lbs.
* For input adjustment
REPLACEMENT PARTS
Note:
 Use only original replacement parts. This 
will  protect  your  warranty  coverage  for  parts 
replaced under warranty. 
PARTS UNDER WARRANTY
Contact  authorized  dealers  of  this  product.  If 
they canʼt supply original replacement part(s), 
call  DESAʼs Technical  Service  Department  at 
1-866-672-6040.
When calling DESA, have ready
•  your name
•  your address
•  model and serial numbers of your firebox 
•  how firebox was malfunctioning
•  type of gas used (propane/LP or natural gas)
•  purchase date
Usually, we will ask you to return the part to the 
factory.
PARTS NOT UNDER WARRANTY
Contact  authorized  dealers  of  this  product.  If 
they canʼt supply original replacement part(s), 
call DESA at 1-866-672-6040 for referral infor-
mation.
When calling DESA, have ready
•  model number of your firebox 
•  the replacement part number
Note:
 The firebox identification label (including 
model number, serial number, clearances, etc.) is 
located on the right front edge of the firebox. 
TECHNICAL SERVICE
You may have further questions about installation, 
operation or troubleshooting. If so, contact DESAʼs 
Technical Service Department at 1-866-672-6040. 
When calling, please have your model and serial 
numbers of your firebox ready.
You can also visit DESAʼs technical services web 
site at 
www.desatech.com
.
SERVICE HINTS
When Gas Pressure Is Too Low
•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply may be low for propane/
LP unit
You may feel your gas pressure is too low. If so, 
contact your local gas supplier.