Sanyo MDF-U7386SC Benutzerhandbuch

Seite von 4
A wide range of Ultra-low              
temperature freezers.
this product family offers different types
and models of ultra-low freezer which can
achieve and maintain temperatures down
to -86ºC (-123ºf) at ambient temperature 
of 30ºC (85ºf). It is  a wide selection, offer-
ing a variety of sizes and types suitable 
for uses such as long term preservation, 
testing, frozen storage etc.
Specially Designed Compressor for
Ultra-Low Temperature.
the refrigeration system is at the heart of
producing ultra-low temperature freezing.
In the process of developing various 
technical solutions in order to achieve and 
maintain ultra-low temperatures, sanyo 
designed a compressor especially for ultra 
low-temperature use. sanyo is a leading 
manufacturer of ultra-low temperature 
freezers that develops and produces all its 
own components, from the refrigeration 
units to the microprocessors.
An Ideal Freezing Environment By
Means of A Double-Insulation Wall 
and the “Hot Line”.
In ultra-low temperature freezers,
effective insulation is extremely critical
since the temperature difference between
the outside and the inner compartment
can be as high as 115ºC. the insulation
used in sanyo’s ultra-low temperature
freezers is two layers of rigid,
foamed in place polyurethane. this design
prevents the insulation layers from
distortion and cracking that might occur
due to temperature differences inside and
out, and creates the most efficient
insulation material available today.
moisture condensation at the top edges
of the cabinet due to differences in
temperature inside and out causes frost
and icing problems, which may reduce
heat insulation efficiency and obstruct
door movements. they are prevented by
the “hot line” by means of which hot gas
from the higher temperature circuit is
circulated through the problem areas.
               
p r e s e r v a t i o n  
                                                                 
p r e s e r v a t i o n
-86°C PRODUCT FAMILY
DESIGN
–80°C
–130°C
–152°C
Recrystallization point
Hexagonal crystal
Cubic crystal
Amorphous 
ice crystal
Why Freeze to –152°C?
Recrystallization Mechanism (Artist’s Concept)
–86
°C
–86
°C
–152
°C
–152
°C
Alarm lamp and buzzer
Filter check lamp
Buzzer key
Alarm test key
Mode setting key
Digit shift key
Numerical value shift key
Enter key
Power switch
CO
2
 Back-up test swich (AT type only)
CO
2
 Back-up swich (AT type only)
Battery switch
Remote alarm switch
Temperature recorder
Control panel
Hot line
MDF-393AT
1
2
3 4 5 6 7 8
9
10
12
13
14
11
1
2
3
4
5
6
7
8
9
10
12
13
14
11
Optional Accessories
Model No.
Recording Range
Freezer Model
MTR-85H
–100 to +50°C
MDF-192
MDF-393
MDF-593
MDF-793
MTR-155H
–170 to +30°C
MDF-1155
ULT-Freezer Backup Kits
CVK-UB2/UB2(I): LCO
2
 Backup Kit for MDF-793/593/393
CVK-UBN2/UBN2(I): LN
2
 Backup Kit for MDF-793/593/393
CVK-A: Built-in LCO
2
 Backup Kit for MDF-793/593/393/192
CVK-AT2: LCO
2
 Backup Kit for MDF-1155
CVK-ATN2: LN
2
 Backup Kit for MDF-1155
Temperature Recorders
(I) version for North America only
MDF-U5386SC
innovation
performance
reliability
support
MDF-U7386SC 
-86°C
23.5 cu.ft.
Evolutionary Design
 the newly developed refrigeration 
system and freezer structure minimizes 
intrusive operating noise.
 the newly developed back cover 
combined with new aerodynamically 
designed and placed components in the 
refrigeration compartment provide supe-
rior air flow, making it possible to drasti-
cally reduce the stress to the freezer and 
contributing to excellent durability.
 two independent and insulated inner 
doors ensure maximum interior chamber 
uniformity.
Safety
 High and low temperature warning pro-
vides an audible and visual alarm when 
the temperature deviates more than ±5°C 
to ±20°C (adjustable) from the set point.
 alarm ring back function ensures that 
buzzer will resume operation, should 
alarm conditions continue after it is 
silenced.
 microprocessor-controlled filter-clog 
check function
 protects the refrigeration circuit.
 Control panel with digital display for 
easy operation.
UPRIGHT -86ºC ACCESSIBILITY
MDF-U5386S
Dimensions
[Unit : mm (inch)]
Specifications
Model
Temperature range
Maximum cooling 
performance
Exterior dimensions
(W x D x H)
Interior dimensions
(W x D x H)
Net weight
Effective capacity
Shelf
Access port
Compressor
Refrigerant
Alarm
Remote alarm contact
Accessories
Power Requirement
MDF-U5386SC
–50°C to –86°C (1°C increment)
–86°C 
(Ambient temp. 30°C)
35.0” x 34.4” x 78.3”
(890 x 875 x 1990mm)
24.8” x 23.6” x 50.4”
(630 x 600 x 1280mm)
672 lbs. (Approx. 305kg) 
17.1 cu.ft. (483 L) 
Stainless steel, Adjustable, 
3 shelves, W608 x D533”, Max. 
load: 50kg (110 lbs.)/shelf
17” diameter, 3 locations (back, 
bottom left/right corner)
Hermetic type, Output: 1100 W 
(high stage side), 1100 W (low 
stage side)
HFC refrigerants
High/low temperature,  
Power failure, Filter check, 
Battery check
Allowable contact capacity: 
DC 30V, 2A
1 set of keys, 1 scraper
220V / 60 Hz 
Built-in voltage booster
*Appearance and specifications are subject to change without notice.
Features
Distributed by:
Pull-down characteristics
40
20
0
–20
–40
–60
–80
–100
0
2
4
6
8
10
5
0
12
35
25
20
14
15
10
Te
m
p
er
at
u
re
 (°
C
)
40
20
0
–20
–40
–60
–80
–100
0
2
4
6
8
10
12
14
Te
m
p
er
at
u
re
 (°
C
)
Time (hour)
Time (hour)
Pull-up characteristics 
during power failure
30
14
8
6
4
2
10
12
0
T
im
(h
o
u
r)
Ambient temperature (°C)
CO
2
 backup system operation 
characteristics
Central air temp. in cabinet
Ambient temp. 30°C, No-load
Ambient temp. and maintenance 
of –70°C by injection of LCO
2
 (30kg)
ACCESSIBILITY
• A new beak style inner 
door latch tightly closes 
the inner door against 
the freezer frame. It 
also helps make 
opening and closing the door smoother.
• The condenser filter is situated at the
bottom right side of the front panel to make 
filter removal and cleaning easier.
SANYO Electric Co., Ltd.
SANYO Sales & Marketing Corporation
5-15, Hiyoshi-cho 2-chome, Moriguchi City, Osaka, 570-8634, Japan
Telephone: +81-6-6992-0322  Fax: +81-6-6992-9291
URL  http://www.sanyo.co.jp/cmg/biomedical
©2006 SANYO  Printed in Japan   2006.3. MA.  SHR102
Performance Data
SAFETY
• Alarm lamp and buzzer offer secure warning 
of power failure or abnormal temperature 
increase.
• High and low temperature warning provides 
an audible and visual alarm when the 
temperature deviates more than 5°C to 
20°C (adjustable) from the set point.
• Alarm ring back function ensures that buzzer 
will resume operation, should alarm 
conditions continue after it is silenced.
• Microprocessor-controlled filter-clog check 
function protects the refrigeration circuit.
• New rugged, one-handed 
outer door latch has a hole to 
allow a padlock to securely 
protect valuable samples.
• Control panel with 
digital display for easy 
operation.
956 (37.6)
890 (35)
18 (0.7)
48
(1.9)
630 (24.8)
1540 (60.6)
450 (17.7)
1990 (78.3)
605.5 (23.8)
105
(4.1)
1280(50.4)
130 (5.1)
130 (5.1)
867 (34.1)
11
(0.4)
1625 (64)
795 (31.3)
140
(5.5)
EVOLUTIONARY DESIGN
• The newly developed refrigeration system 
and the freezer structure offer a quiet 
experimental environment.
• Achieves 10% higher energy conservation 
than previous model. 
(For model rated 220V, 50Hz)
• The newly developed back cover combined
with new aerodynamically designed and 
placed components in the refrigeration 
compartment provide superior air flow, 
making it possible 
to drastically 
reduce the stress 
to the freezer and 
contributing to 
excellent durability.
• Two independent and insulated inner doors
prevent cold air leakage.
Back 
cover
Compressors
Front
Rear
Air
ISO 9001 & 14001 certified
Options
Circular recorder 
MTR-C954
MTR-85H
Recorder mounting 
bracket 
MDF-S3085
(for MTR-85H)
LCO
2
 backup system
CVK-UB2
LN
2
 backup system
CVK-UBN2
Inventory rack 
SUR-624-I
Rack Capacity: 24
*Cooling performance is indicated by the temperature reached at 
the center of the freezer (at ambient temperature of 30C with no 
load). In order to use the freezer at a stable temperature for a long 
time, it is recommended that the temperature be set to at least 5C 
higher than the indicated lowest temperature. 
In addition, depending on the usage conditions, it may not be 
possible to reach the indicated lowest temperature.
-86°C
17.1 cu.ft.