Monitoring NetAXS™ Status
Monitoring Inputs
4.4  Monitoring Inputs
A NetAXS™ panel supports door, panel, and auxiliary inputs. The door inputs provide egress and 
tamper status, the panel inputs provide power fail and tamper status, and the auxiliary inputs support 
any downstream status.
Click 
Status > Inputs
 to display the Input Status screen:
Figure 4-5:   Status > Inputs
The Input Status screen enables you to: 
• View the current status of each input (Normal, Alarm, Cut, Short, Shunted).
• Shunt or un-shunt any input. When an input is shunted, the alarm is de-activated. This is a way 
you can allow the input to grant access without falsely signalling an alarm. The default state of 
an input point is “un-shunted.”
• Restore the input to its configured time zone. A time zone is a specified time period during 
which the input will be shunted and the alarm de-activated. (see “