(d)  If the "new acceleration/deceleration time" is set to "0" and the speed is 
changed after the "new acceleration/deceleration time" is validated, the 
operation will be controlled with the previous "new acceleration/deceleration 
time". 
 
 
 
(e)  During JOG operation, the acceleration/deceleration time change function 
does not function. 
 
POINT 
 
If the speed is changed when an acceleration/deceleration change is enabled, the 
"new acceleration/deceleration time" will become the acceleration/deceleration time 
of the positioning data being executed. The "new acceleration/deceleration time" 
remains valid until the changeover to the next positioning data. (The automatic 
deceleration processing at the completion of the positioning will also be controlled 
by the "new acceleration/deceleration time".) 
 
(3)   Setting the acceleration/deceleration time change function 
To use the "acceleration/deceleration time change function", write the data 
shown in the following table to the D75P2 using the sequence program.  
The set details are validated when a speed change is executed after the details 
are written to the D75P2.  
 
Setting item 
Setting 
value 
Setting details 
Buffer memory address
Axis 1 
Axis 2 
Cd.33  
New acceleration 
time value 
 
Set the new acceleration time. 
1184 
1185 
1234 
1235 
Cd.34  
New deceleration 
time value 
 
Set the new deceleration time. 
1186 
1187 
1236 
1237 
Cd.35  
Acceleration/ 
deceleration time 
change during 
speed change, 
enable/disable 
selection 
Set "1: Acceleration/deceleration time change 
enable". 
1188 1238 
 
                 * Refer to section "5.7 List of control data" for details on the setting details.