Make the Electrical Connection
1. Disconnect power.
2. Determine the location where the wiring conduit will be 
routed through the ceiling or wall between the makeup air 
switch duct and the motorized damper.
3. Drill a hole at this location.
4. Locate the electrical terminal boxes in the makeup air switch 
duct and the motorized damper.
Remove the terminal box covers and set the covers and 
screws aside.
5. Determine the knockouts in terminal boxes for motorized 
damper, makeup air switch duct and house junction box that 
will be used. 
Remove knockouts and install a ½" (12.7 mm) UL listed or 
CSA approved strain relief at each location.
6. Run separate wiring between the house junction box and the 
terminal boxes for the motorized damper and the makeup air 
switch duct. 
7. Connect green (yellow/green) wires from makeup air switch 
duct and motorized damper to house ground using UL listed 
wire connectors.
8. Connect brown wire from makeup air switch duct to the black 
wire(s) from the motorized damper using UL listed wire 
connectors.
9. Connect black wire from makeup air switch duct to the house 
line black wire using a UL listed wire connector.
10. Connect the white wire(s) from the motorized damper to the 
house neutral white wire(s) using UL listed wire connectors.
NOTE: The 10" (25.4 cm) Makeup Air Kit must be installed 
with 2 motorized dampers. The lightest figure shown is the 
connection for the second motorized damper.
Check Operation
Once the make up air switch duct and the motorized damper(s) 
are installed, the installer should confirm that the motorized 
damper opens and closes in conjunction with signals from the 
hood. 
The motorized damper should close or be closed when 
the range hood speed switch is Off or On at low speed.
The motorized damper should open when the range hood 
speed switch is set at medium speed or higher.
A qualified HVAC contractor should also ensure the proper 
operation and venting of all combustion equipment in the home.
Makeup Air Kit Maintenance
Regular maintenance is necessary to ensure the proper operation 
of the makeup air system. Failure to conduct routine maintenance 
can reduce the ability of the damper to introduce fresh air into the 
home. Regular maintenance should include the following 
activities: 
Maintain a clear opening at the outdoor end cap, keeping 
snow, leaves or vegetation from building up at the end 
cap. 
Clean or replace the interior filter(s) that serve to filter 
fresh air before it enters the home. 
During regular HVAC maintenance, have the mechanical 
contractor inspect the damper system for proper 
operation.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Connect ground wire to green ground wire in terminal 
box.
Replace all parts and panels before operating.
Failure to do so can result in death, fire, or 
electrical shock.
House
ground
House
neutral
House
neutral
House
line
House
ground
120VAC
white
brown
black
green
wall
yellow/
green
green
black
white
House
ground
black
10" (25.4 cm) Makeup air installation
black