Pre-installation Information
Before You Begin...
Before unpacking, inspect the carton for exterior damage. If 
you fi nd damage, advise the delivery carrier of a potential 
claim. Inspect your package carefully. You can check your 
accessory box parts with the enclosed packing slip for your 
convenience. Claims for shortages will be honored for only 
30 days from the date of shipment.
Before installing the operator, read this manual completely to 
ensure all requirements for proper installation are present. Verify 
that the voltage to be used matches the voltage of the operator.
If you have any questions about the requirements for proper 
installation of this gate operator contact technical support at 
800-421-1587
Always Check the Gate’s Action
It’s very important before installing the gate operator to 
make sure the gate’s swing is free and level throughout 
the entire swing path. If the gate does not seem to 
operate properly, it may affect the operator performance 
or greatly shorten the life of the unit. The gate should 
also be designed so that airfl ow is ample to prevent 
wind resistance and drag.
Gate Operator Classifi cations
All gate operators can be divided into one of four different 
classifi cations, depending on their design and usage. Install 
this gate operator only when the operator is appropriate for 
the construction and usage class as defi ned below:
Class I Residential Vehicular Gate Operator
• 
A vehicular gate operator intended for use in a home or for one to 
four single family dwellings with a common garage or parking area 
associated with these dwellings.
Class II Commercial / General Access Vehicular Gate Operator
• 
A vehicular gate operator intended for use in a commercial location or 
building such as a multi-family housing unit of fi ve or more single family 
units, hotel, retail store or other building servicing the general public.
Class III Industrial / Limited Access Vehicular Gate Operator
• 
A vehicular gate operator intended for use in an industrial location or 
building such as a factory or loading dock area or other location not 
intended to service the general public.
Class IV Restricted Access Vehicular Gate Operator
• 
A vehicular gate operator intended for use in a guarded industrial 
location or building such as an airport security area or other restricted 
access locations not servicing the general public, in which unauthorized 
access is prevented via supervision by security personnel.
Approved Obstruction Detection Devices
The following contact or non-contact obstruction detection 
devices have been approved for use with this swing gate 
operator as part of a UL325 compliant installation:
Contact Edges
• 
Miller Edge Models MGO20, MGR20, MGS20, ME120
Photoeyes
• 
MMTC Model IR-55 (165’ range - P/N 2520-441)
MMTC Model E3K (28’ range - P/N 2520-031)
Safety Information and Warnings
Regulatory Warnings
Read the following before beginning to install this swing 
gate operator:
THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES
IN THESE INSTRUCTIONS.
 WARNING 
This type of warning note is used to 
indicate possible mechanical hazards that 
may cause serious injuries or death.
 CAUTION 
This type of warning note is used to 
indicate the possibility of damage to the 
gate or gate operator.
 WARNING 
This type of warning note is used to indicate 
possible electrical shock hazards that may 
cause serious injuries or death.
IMPORTANT INSTALLATION SAFETY INSTRUCTIONS
  WARNING 
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH 
TO PERSONS, REVIEW THESE INSTALLATION SAFETY 
STEPS BEFORE PROCEEDING
  1.  READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
  2.  Read the yellow “Safety Instructions” brochure enclosed with the 
packet of information. If any pages are missing or are unreadable, 
or you do not have the safety instructions, please call Linear at 
1-800-421-1587 to request additional copies.
  3.  ALL ELECTRICAL CONNECTIONS TO THE POWER SUPPLY MUST 
BE MADE BY A LICENSED ELECTRICIAN AND MUST OBSERVE ALL 
NATIONAL AND LOCAL ELECTRICAL CODES.
 4. A separate power-disconnect switch should be located near the 
operator so that primary power can be turned off when necessary.
  5. Install the enclosed warning signs on both sides of the gate. A 
minimum of two (2) WARNING SIGNS shall be installed, one on each 
side of the gate where easily visible.
  6.  Never reach between, through or around the fence to operate the 
gate.
  7.  Never connect a button station within reach of the gate or on the 
side of the gate operator.
  8.  Do not adjust the operator controller’s current sensing feature too 
high. It should be adjusted high enough to keep the gate from falsely 
triggering the sensing, but no higher than necessary for the gate to 
operate. DO NOT DEFEAT THE PURPOSE OF THIS FUNCTION!
  9.  You must install all required safety equipment.
 10.  UL325 Compliance requires the use of contact edges or photoelectric 
controls on all automatic or remotely-controlled gate operators.
 11. The operator is intended for installation only on gates used for 
vehicles. Pedestrians must be supplied with a separate access 
opening. The pedestrian access opening shall be designed to 
promote pedestrian usage. Locate the gate such that persons will 
not come into contact with the vehicular gate during the entire path 