21.4
 
Data Format 
21.4.1
 
Transmission Format 
Figure 21.6 shows the relationship between the transfer format and each register during the IEBus 
data transmission. 
IETBFL
IEMCR
[In master transmission]
[In slave transmission]
Communications frame
Communications frame
Register
Register
Notes:
1. 
In slave transmission, the received master address is not saved. If the unit is locked,
 
address comparison performed. 
2. 
The received slave address is compared with IEAR1 and IEAR2, and if these addresses
 match, 
operation 
continues.
3. 
In slave transmission, the received control bits are not saved. The received control bits
 
are decoded to decide the subsequent operation.
IETB001 to IETB128
Message length bits
Data bits
Slave address
Master address
Control bits
Message length bits
Data bits
Slave address
Master address
Control bits
IESA1, IESA2
IEAR1, IEAR2
(*1)
(*3)
(*2)
IEAR1, IEAR2
IETBFL
IETB001 to IETB128
 
Figure 21.6   Relationship between Transfer Format and Each Register during IEBus Data 
Transmission