en | Safety
FLEXIDOME HD
AM18-Q0615 | v1.0 | 2012.10
Installation Manual
Bosch Security Systems
1.3
Connection in applications
Grounding
The yellow/green safety (power) ground wire from the camera 
must be connected to the system earth of the installation.
U.S.A.: - section 810 of the National Electrical Code, ANSI/NFPA 
No.70, provides information regarding proper grounding.
12 VDC / 24 VAC power source: This unit is intended to 
operate with a limited power source. The unit is intended to 
operate at either 12 VDC or 24 VAC (if PoE is not available). 
User supplied wiring must be in compliance with electrical 
codes (Class 2 power levels). 
PoE: Use only approved PoE devices. Power-over-Ethernet can 
be connected at the same time as a 12 VDC or 24 VAC power 
supply. 
If auxiliary power (12 VDC or 24 VAC) and PoE is applied 
simultaneously, the camera selects auxiliary input and shuts off 
the PoE.
1.4
Type label
The type label is located on the rear of the camera module.