Lennox International Inc. GWB8-112IE-2 Benutzerhandbuch

Seite von 32
20
Operating Instructions. 
1. 
STOP! Read Safety Information on previous page.
2. 
Set the thermostat to lowest setting.
3. 
Turn off all electric power to the appliance.
4. 
This appliance is equipped with an ignition device which 
automatically lights the burner. Do not attempt to light 
pilot by hand.
5. 
Remove burner access panel.
OFF
ON
INLET
GAS CONTROL KNOB
SHOWN IN "ON" POSITION
6. 
Depress gas control knob slightly and turn clockwise 
 to “OFF” position.
7. 
Wait fi ve (5) minutes to clear out any gas. If you then 
smell gas STOP! Follow WHAT TO DO IF YOU SMELL 
GAS. If you don’t smell gas, go to next step.
8. 
Turn gas control knob counterclockwise 
 to “ON.” 
9. 
Turn on all electric power to the appliance.
10. 
Set thermostat to desired setting.
11. 
After visually inspecting the fl ame, replace lower front 
panel.
12. 
If appliance will not operate after several tries, turn gas 
control knob to “OFF” and call your service technician 
or gas supplier.
To Turn Off Gas To The Appliance
1. 
Set the thermostat to lowest setting.
2. 
Turn off all electric power to the appliance if servicing is 
to be performed.
3. 
Depress gas control knob slightly and turn clockwise 
 to “OFF” position. Do not force.
STARTING YOUR BOILER
Figure 11   - Gas Control Knob
 WARNING
If you do not follow these instructions 
exactly, a fi re or explosion may result 
causing property damage, personal injury 
or loss of life.
• This appliance is equipped with an ignition device 
which automatically lights burner. Do NOT try to 
light this burner by hand.
• Before operating smell all around appliance area 
for gas. Be sure to smell next to fl oor because 
some gas is heavier than air and will settle to the 
fl oor.
• Use only your hand to turn the gas shutoff 
valve. Never use tools. If valve will not turn by 
hand, do not try to repair it, call a qualifi ed ser-
vice technician. Force or attempted repair may 
result in fi re or explosion.
• Do not use this appliance if any part has 
been under water. Immediately call a qualifi ed 
service technician to inspect appliance and to 
replace any part of control system and any gas 
control which has been under water.
!
  
LIGHTING PROCEDURE FOR BOILER WITH 
INTERMITTENT PILOT SYSTEM
For Your Safety, Read Before Operating!!
A.  This appliance is equipped with an ignition device 
which automatically lights the pilot. Do not try to light 
appliance by hand.
CAUTION
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switches; do not use 
any phone in your building.
• Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions. 
• If you cannot reach your gas supplier, call the fi re 
department.
!
!