AC Line Voltage:
Single phase 120V, 60Hz, AC only 
AC Power Required:
1650 W 14.3 amps. 
Output Power*:
1000 watts
Frequency:
2450 MHz
Outside Dimensions (including handle):
29  
15
/
16
”(W) x 17 
1
/
16
”(H) x 18 
15
/
32
”(D)
Cavity Dimensions:
22 
1
/
2
”(W) x 10 
1
/
16
”(H) x 14 
31
/
32
”(D)
Microwave oven Capacity**:
1.8 Cu.Ft.
Weight:
Approx. (net) 61 lb, (gross) 73 lb
Work/Night Light:
2 bulbs 20w each (incandescent light bulbs)
SERVICE CALL CHECK
SPECIFICATIONS
Please check the following before calling for service:
  Place one cup of water in a glass measuring cup in the oven and close the door securely.
  Operate the oven for one minute at HIGH 100%.
A  Does the oven light come on?
YES ____
NO ____
B  Does the cooling fan work? 
(Put your hand over the left side of louver.)
YES ____
NO ____
C  Is the water in the oven warm?
YES ____
NO ____
If A is "NO", then  you need to check light bulb.  See 
page 27 for removal.
If “NO” is the answer to any of the above questions, 
please check electrical outlet, fuse and/ or circuit 
breaker. If they are functioning properly, CONTACT 
YOUR NEAREST ELECTROLUX AUTHOR IZED 
SERVICER.
A microwave oven should never be serviced by a 
“do-it-yourself” repair person.
*  The International Electrotechnical Commission’s standardized method for measuring output wattage. This test method 
is widely recognized. 
** Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is 
less.
In compliance with standards set by:
FCC 
-  Federal Communications Commission Authorized.
DHHS - 
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J.
 
-  This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
NOTES
1.  If time appearing in the display is counting down 
very rapidly, check Demonstration Mode on page 25 
and cancel.
2.  If the oven is set for 40 minutes and over at 80, 
90 or 100 percent power level, after the fi rst 40 
minutes the power level will automatically adjust 
itself to 70 percent power to avoid overcooking.