2.2 Customer Premises Wiring
Outputs supplied on two RJ45 jacks. Pins are numbered (left-to-right) 1 to 8 as seen
from the open end with tab facing downward.
from the open end with tab facing downward.
PIN#
LVDS SIGNAL
OUTPUT
RS422 SIGNAL
OUTPUT
1
GND
GND
2
LD+
RD+
3
LD-
RD-
4
LS+
RS+
5
LS-
RS-
6
LC+
RC+
7
LC-
RC-
8
GND
GND
Table 1. RJ-45 Pin-outs
3. CONTROL AND STATUS INDICATIONS
Note: Sync Data option card may be setup by your network and local control may be disabled. If
so, only the status monitoring will be possible.
so, only the status monitoring will be possible.
3.1 From Terminal
Ÿ Sync data card setup with local control disabled:
The sync data card setup cannot be accessed via the terminal with local control
disabled. Local control will have to be authorized by the network.
disabled. Local control will have to be authorized by the network.
Ÿ Sync data card setup with local control enabled :
CSD cmd param port
Cmd: R - Set RS422 output state
Cmd: R - Set RS422 output state
L - Set LVDS output state
D - Set data rate
P - Set PID
Param:E/D - Enable/disable output ports (used with R & L commands)
64.0 - 6875 Kbps - data rate range (used with D command)
0x0020 - 0x1FFE - PID range (used with P command)
Port: port number (1 or 2)
Ÿ
Sync data card status