Wegener Communications Unity Satellite Receiver Model Unity Synchronous Data Option Benutzerhandbuch

Seite von 5
3
UTY4000-007
 
2.2   Customer Premises Wiring
Outputs supplied on two RJ45 jacks.  Pins are numbered (left-to-right) 1 to 8 as seen
from the open end with tab facing downward.
PIN#
LVDS SIGNAL
OUTPUT
RS422 SIGNAL
OUTPUT
1
GND
GND
2
LD+
RD+
3
LD-
RD-
4
LS+
RS+
5
LS-
RS-
6
LC+
RC+
7
LC-
RC-
8
GND
GND
Table 1.  RJ-45 Pin-outs
3.   CONTROL AND STATUS INDICATIONS
Note:  Sync Data option card may be setup by your network and local control may be disabled.  If
so, only the status monitoring will be possible.
3.1  From Terminal
Ÿ  Sync data card setup with local control disabled:
The sync data card setup cannot be accessed via the terminal with local control
disabled.  Local control will have to be authorized by the network.
Ÿ  Sync data card setup with local control enabled :
 
CSD cmd param port
Cmd: R - Set RS422 output state
 
L - Set LVDS output state
 
D - Set data rate
 
P - Set PID
 
Param:E/D - Enable/disable output ports (used with R & L commands)
 
64.0 - 6875 Kbps - data rate range (used with D command)
 
0x0020 - 0x1FFE - PID range (used with P command)
 
Port: port number (1 or 2)
 
 
 
 
Ÿ 
Sync data card status