Dimension
14.5 mm
85
 mm 
MAX
LCL 
52
 ±
 1.0
 mm 
1.0 mm 
12.0 mm 
Lamp life
Life survival graphs are shown for statistically representative batches of lamps operated under controlled nominal conditions 
with a 7 hours per start switching cycle. Declared lamp life is the median value, i.e. when 50% of lamps from a large sample 
batch would have failed. Lamp life in service is affected by a number of parameters, including supply voltage variation, 
switching cycle, operating position, ballast impedance tolerance, luminaire design and mechanical vibration.
The information provided is intended to be a practical guide for comparison with other lamp types. Determination of lamp 
replacement schedules will depend upon relative costs of spot or group replacement and acceptable reduction in lighting 
levels.
Note: Representative curves are shown for Vertical Base-Up lamp orientation unless otherwise specified. Life performance is 
significantly increased in the Horizontal burning position.
40%
20%
  0%
60%
80%
100%
4
6
8
10
12
0
2
Burning times (thousand hours)
% Lamp sur
viv
al 
CMH 20W G8.5 3000K
40%
20%
  0%
60%
80%
100%
4
6
8
10
12
14
0
2
Burning times (thousand hours)
% Lamp sur
viv
al 
CMH 35W G8.5 3000K and 4200K
40%
20%
  0%
60%
80%
100%
4
6
8
10
12
14
0
2
Burning times (thousand hours)
% Lamp sur
viv
al 
CMH 70W G8.5 3000K and 4200K