Heat Controller HTD SERIES Benutzerhandbuch

Seite von 29
Heat Controller, Inc. 
HTV/HTD/HTH  SERIES
 
Engineering Design Guide
2
Two Stage Geothermal Heat Pump Systems
Features of the Two Stage HT Series
The HT Series Geothermal Heat Pumps are some of the most efficient and innovative geothermal units on the market today. 
Packed with features, they offer the best value to the homeowner who is interested in quiet comfort and low operating costs  
as a result of extraordinary efficiencies.
Technically, the HT Series are state-of-the-art with digital electronic controls, multi-stage scroll compressors, computer  
controlled fan motors, zero ozone depleting refrigerant, and much more.
Design Features
•  Five capacities to meet all application requirements—two, 
three, four and six ton models.
•  Efficient operation from 20°F to 120°F entering water tempera-
tures. Flow rates may be as low as 1.6 gpm/ton.
•  Top supply air discharge accommodates upflow applications.
•  Select left or right hand return air positions for all models;  
cabinets include a deluxe filter rack/duct collar.
•  Variable speed ECM blower motor adjusts to multiple duct 
system applications and provides soft start for added comfort 
and quiet operation.
•  Narrow cabinet design can be easily moved through doorways.
•  Internally trapped condensate piping (on all vertical units)  
allows easy, compact installation.
•  Internal electric heat unit (optional) is designed for easy field 
installation.
•  Electric box is positioned for easy field wiring from two sides.
•  Loop pump power block is built with circuit breaker.
•  Coaxial low temperature protection can be selected in the field 
for well or closed loop installations.
•  Air coil low temp. protection utilizes high accuracy thermistors.
•  Coaxial heat exchanger, refrigerant suction lines, hot water 
generator coil, and all water pipes are fully insulated to reduce 
condensation in low temperature conditions.
•  Isolation mounted compressors and low RPM blowers are used 
to reduce noise; compressor compartment and interior cabinet 
are insulated with 1/2" coated glass fiber insulation.
•  Double isolated compressor delivers extra quiet operation.
•  Safety features include: high pressure and loss of charge pro-
tection for the compressor; condensate overflow protection; low 
temperature protection sensors to safeguard the coaxial heat 
exchanger and air coil; hot water high-limit hot water genera-
tor pump shutdown; fault lockout that enables emergency heat 
and prevents compressor operation until thermostat or circuit 
breaker has been reset.
Operating Efficiencies
•  AHRI/ASHRAE/ISO 13256-1 ratings for heating COPs and 
cooling EERs are industry leaders.
•  Hot water generator (HWG) with internal pump generates hot 
water at dramatic savings while improving system performance.
•  Efficient scroll compressors provide quiet, reliable operation.
•  Oversized coaxial tube water-to-refrigerant heat exchanger 
delivers high efficiency and extra heating capacity; convoluted 
water tube functions efficiently at low flow rates and provides 
resistance to freeze damage.
•  Oversized rifled copper tube/lanced aluminum fin air-to-refriger-
ant heat exchanger offers high efficiencies at low air velocity.
•  Large, low RPM blower is both quiet and efficient, and provides 
high static capability.
Service Advantages
•  Three removable access panels for the compressor compartment 
and one or two (depends on model) for the air handler compart-
ment offer quick access to all internal components even with 
ductwork in place, making the unit service-friendly.
•  Built with bi-directional thermal expansion valve.
•  Brass, swivel water connections make it easy to connect loop 
and hot water piping.
•  Insulated divider and separate air handling/compressor access 
panels allow service testing without air bypass.
•  Design allows in-place service in tight installation spaces.
•  CXM control features LED status light with memory feature for 
easy diagnostics.
•  Control box and fan motors have quick-attach wiring connections 
for fast removal/reconnection.
•  Biflow liquid line filter drier is factory-installed.
•  75 VA control transformer comes with circuit breaker.
•  Internal drop-out blower assemblymakes servicing simple.
•  Refrigerant circuit includes high and low pressure service ports.
•  E-coated refrigerant-to-air coil helps protect the coil from  
corrosion and extends life expectancy.
Factory Quality
•  All units are built using our state-of-the-art manufacturing system 
that is designed to assure quality of the highest standards. This 
system:
  -Verifies that the correct components are being assembled;
  -Automatically performs special leak tests on all joints;
  -Conducts pressure tests;
  -Performs a highly detailed run test;
  -Automatically prevents a "failed" unit from being packaged for  
  shipment;
  -Creates a computer database of run tests for future service 
    analysis and diagnostics;
  -Includes painting heavy gauge steel cabinets with durable epoxy
    for  a long-lasting finish;
  -Performs all refrigerant brazing in a nitrogen-rich environment;
  -Evacuates units to a deep vacuum of less than 50 microns  
     prior  to  refrigerant charging
  -Halogen leak tests all joints to ensure a leak rate of less 
    than 1/4 ounce per year.
Options & Accessories
•  Optional internal auxiliary electric heat.
•  Electronic auto-changeover thermostats with indicator LEDs.
•  Closed loop flow controller and hose kits.
See Geo Accessories brochure for complete list of accessories.