30 www.goodmanmfg.com 
SS-CPC36-72
w
iring
 d
iagram
 —
 CpC036/48*1d (s
ingle
 p
hase
, d
ireCt
 d
riVe
)
H
1
RCCF
T
PU
CONTROL
BR
C
2
T1
S
T1
GR
BK
O
1
YL
4
BR
1
BR
T1
BK
9
RD
COMP
R
BR
RCCF
T2
3
C
W2
T
Y1
PLF 1
3
T
YL/PK
PU
F
BL
3 6
7
5
PU
T3
G
T2
COMPONENT LEGEND
BL
L1
SUPPLY VOLTAGE
CM
BK
R
EM
/
L1
4
C
RD
YL
6
0
BC
BIR
C
CM
COMP
EM
GND
HPS
LPS
PLF
RCCF
TB1
TR
WH
C
A
GR
CM
W1
YL
8
E
RD
M
C
C
2
PU
S
L2
BLOWER CAPACITOR
BLOWER INTERLOCK RELAY
CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUPIMENT GROUND
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
CONDENSER FAN
TERMINAL BLOCK (24V SIGNAL)
TRANSFORMER
TR
BOX
OF OVER CURRENT PROTECTION
PLF 2
BL
BK
5
++
YL
COMP
SEE UNIT RATING PLATE FOR TYPE AND SIZE
208-240V
O
208-240/1/60
R
2
0
8
-
2
4
0
BK
Y/Y2
/
GND
6
1
PB
TB1
BL
BL
208-240/1/60   0140L00504  REV A
SEE NOTE 3
24V
RD
RD
T2
L2
NOTES:
1.  REPLACEMENT WIRE MUST BE SAME SIZE AND
     TYPE INSULATION AS ORIGINAL (AT  LEAST
     105°C) USE COPPER CONDUCTOR ONLY.
2.  TO CHANGE EVAPORATOR MOTOR SPEED MOVE
     M1 OR M2 WIRE TO COM TERMINAL ON EBTDR
     AND PLACE WIRE REVMOVED FROM COM ON
     EMPTY M1 OR M2 TERMINAL.
3.  FOR 208 VOLT TRANSFORMER OPERATION
     MOVE BLACK WIRES FROM TERMINAL
     3  TO TERMINAL 2 ON TRANSFORMER.
4.  USE COPPER CONDUCTORS ONLY ++  USE N.E.C.
     CLASS 2 WIRE
5.  ECONOMIZER PLUG LOCATED IN THE RETURN
     AIR COMPARTMENT. REMOVE MALE PLUG AND
     ATTACH FEMALE PLUG TO ECONOMIZER
     ACCESSORY.
6. DIAGRAM SHOWS FACTORY SPEED TAP SETTINGS.
WH
GR
TB1
F
LPS
YL/PK
YL
BL
RD
OR
Y1
Y/Y2
YL
W
Y/Y2
BL
G
R
OR
W
NO ECONOMIZER
G
OR
YL
RD
Y/Y2
Y1
PK
WH
W
R
RD
WH
GR
C
O
R
YL
O
GR
Y1
G
WH
WITH ECONOMIZER OPTION
C
GR
THERMOSTAT
FIELD WIRING
BL
C
O
2 STAGE COOLING
TB1
G
R
W
Y2
C
O
TB1
TB1
Y
W
O
R
G
C
W
Y2
G
R
C
O
Y1
STAT
STAT
STAT
C
BL/PK
HPS
BL
PU
BR
C
RD
2
3
K1
RD
BK
BK
BC
BK
24V
COM
TR
UP
BL
M2
BK
240
GR
NC
SPEED
EBTDR
PU
R
XFMR-R
XFMR-C
BL
G
K1
M1
EM
NO
1
SEE
NOTE #2
RD
PU
BL
C
3 SPEED
BR
BL
BK
208
SMOKE/FIRE DETECTOR
REPLACES JUMPER
TB1
S2
S1
PK
RD
BK
RD
BR
BL
BIR
BK
BR
EBTDR
BR
8
9
7
R
O
HPS
C
LPS
SEE NOTE 5
Y/
Y2
TB1
5
6
PLF
G
C
Y1
W1
4
THERMOSTAT
W2
2
PLF2
1
3
6 5 4
R
R
C
G
EBTDR
XFMR
PU
ALTERNATE
MOTOR
6-WIRES
SEE TABLE 1
BC
3 SPEED
BL
EM
RD
BK
BR
RD
PU
TABLE 1
ALTERNATE MOTOR WIRING
TABLE 2
SPEED TAPS
COLOR
RD
BK
BL
PU
TERMINATION
COM (EBTDR)
M1 (EBTDR)
M2 (EBTDR)
PIN 1 (24V XFMR)
RD
BL
BK
LOW
MED
HIGH
H
BL
OR
BK
BK
PU
LOW VOLTAGE
     LINE VOLTAGE
FIELD WIRING
     LOW VOLTAGE
OPTIONAL
HIGH VOLTAGE
FACTORY WIRING
HIGH VOLTAGE
GR   GREEN
WIRE CODE
BL   BLUE
PU   PURPLE
PK   PINK
WH   WHITE
BK   BLACK
RD   RED
BR   BROWN
OR   ORANGE
YL   YELLOW
BL/PK   BLUE WITH PINK STRIP
YL/PK   YELLOW WITH PINK STRIP
YL
1
3
2
OR
RD
H
Wiring is subject t
o chang
e. Alw
ay
re
fer 
to the wiring diagr
am or the 
unit 
for the mos
t up-t
o-da
te 
wiring.
    
W
arning
High 
Volt
ag
e:
 Disc
onn
ect 
all 
po
w
er
 be
for
ser
vicing 
or 
in
st
alling 
this 
unit. 
Multiple 
po
w
er 
 
sour
ces 
ma
be pr
esen
t. F
ailur
to do 
so ma
cause pr
operty 
damag
e, 
per
sonal 
injur
y, 
or dea
th.