Smeg DO10PSS-5 Benutzerhandbuch

Seite von 25
Instructions for the installer
 
 
 
50 
15.  INSTALLATION 
 
15.1  Technical information 
 
 
Oven type 
See rating plate 
 
Electrical connections 
230 - 240 / 400-415 V 3N ~ 50 Hz 
 
Required protection fuse for the oven 
30 Amps 
 
 
OVEN RATING 
 Ovens 
Electric 
 
Maximum electrical power 
6.1 kW 
 Oven 
grilling 
Electric 
 
Large grilling power 
3.0 kW (230 V) 
 
Small grilling power 
1.8 kW (230 V) 
 
Ovens lightings 
25 W    (230 V) 
 
Large oven 
Small oven 
OVEN CAVITY DIMENSIONS 
 Height 
(cm) 
34 
23 
 Width 
(cm) 
46 
46 
 Depth 
(cm) 
40 
40 
 Internal 
volume 
(cm
2
) 62560 
42320 
15.2  The rating plate 
 
CHECK THAT MAINS VOLTAGE AND POWER CABLE RATINGS ARE AS PER THE INDICATIONS 
PROVIDED ON THE LABEL ATTACHED TO THE OVEN DOOR FRAME.  
THIS LABEL MUST NEVER BE REMOVED.
 
 
 
 
 
 
 
Model   
 
      Serial N° 
15.3  Electrical connection 
 
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE 
METHODS REQUIRED BY SAFETY RULES.
 
 
WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT BOTH ARE 
COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE COMPLYING WITH 
APPLICABLE REGULATIONS. 
 
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN. 
NEVER UNPLUG BY PULLING ON THE CABLE.
 
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE OVEN, 
FOLLOWING THE INSTRUCTIONS. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT 
IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE. 
 
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
 
IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG AND 
SOCKET ARE COMPATIBLE. AVOID USE OF ADAPTERS AND SHUNTS AS THESE COULD 
CAUSE OVERHEATING AND RISK OF BURNS.
 
 
IF A FIXED CONNECTION IS BEING USED FIT POWER LINE WITH AN OMNIPOLAR CIRCUIT 
BREAKER WITH A CONTACT OPENING GAP EQUAL TO OR GREATER THAN 3 MM IN AN 
EASILY ACCESSIBLE POSITION IN PROXIMITY TO THE OVEN.