Dimplex LI 11MER Benutzerhandbuch

Seite von 24
www.dimplex.de
E-9
English
11
11 Device Information
1
Type and order code
LI 11MER
2
Design
2.1
Model
Reversible
2.2
Degree of protection according to EN 60 529
 IP 21
2.3
Installation location
Indoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
°C / °C
Up to 58 / above 18
Cooling, flow
°C
+7 to +20
Air (heating)
°C
-25 to +35
Air (cooling)
°C
+15 to +40
3.2
Temperature spread of heating water
at A7 / W35
9.6
5.0
3.3
Heat output / COP 
at A-7 / W35 
1
kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting
capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: External temperature 2 °C
and heating water flow temperature 55 °C.
7.5 / 2.8
7.0 / 2.7
at A-7 / W45 
1
kW / ---
6.8 / 2.3
at A2 / W35 
1
kW / ---
8.9 / 3.4
8.8 / 3.3
at A7 / W35 
1
kW / ---
11.1 / 4.2
11.1 / 4.0
at A7 / W45 
1
kW / ---
9.4 / 3.5
at A10 / W35 
1
kW / ---
12.1 / 4.6
12.0 / 4.4
3.4
Temperature spread of cooling water
at A35 / W7
K
6.5
5.0
3.5
Cooling capacity / COP
at A27 / W7
kW / ---
8.8 / 2.8
8.8 / 2.8
at A27 / W18
kW / ---
10.9 / 3.3
10.8 / 3.2
at A35 / W7
kW / ---
7.6 / 2.1
9.5 / 2.5
at A35 / W18
kW / ---
9.5 / 2.5
9.5 / 2.5
3.6
Sound power level device / outdoors
dB(A)
55 / 61
3.7
Sound pressure level at a distance of 1 m (indoors)
dB(A)
50
3.8
Heating water flow with an internal pressure differential of m³/h / Pa
1.0 / 3000
1.9 / 10900
3.9
Cooling water flow with an internal pressure differential ofm³/h / Pa
1.0 / 3000
1.3 / 5900
3.10 Air flow rate with an external static pressure differential of  m³/h / Pa
4200 / 0
m³/h / Pa
2500 / 25
3.11 Refrigerant; total filling weight
Type / kg
R404A / 3.6
4
Dimensions, connections and weights
4.1
Device dimensions 
H x W x L cm
136 x 75 x 88
4.2
Device connections to heating system
Inch
G 1 1/4'' external
4.3
Air duct inlet and outlet (min. internal dimensions)
L x W cm
50 x 50
4.4
Weight of the transportable unit(s) incl. packing
kg
205
5
Electrical Connection
5.1
Nominal voltage; fuse protection
V / A
230 / 25
5.2
Nominal power consumption 
1
 A2 
W35
kW
2.61
2.67
5.3
Starting current with soft starter
A
38
5.4
Nominal current A2 W35 / cos
ϕ
A / ---
14.2 / 0.8
14.5 / 0.8
6
Complies with the European safety regulations
2
2. See CE declaration of conformity
7
Additional model features
7.1
Defrosting
Automatic
Type of defrosting
Reverse cycle
Defrosting tray included 
Yes (heated)
7.2
Heating water in device protected against freezing
Yes
3
3. The heat circulating pump and the heat pump controller must always be ready for operation.
7.3
Performance levels
1
7.4
Controller internal/external
External