Desa VN2550ITA Benutzerhandbuch

Seite von 40
30
101822
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.
VN1800ITA
VN2550ITA
Btu (Variable)
6,600-18,000
7,000-25,500
Type Gas
Natural Only
Natural Only
Ignition
Piezo
Piezo
Pressure Regulator Setting
6" W.C.
6" W.C.
Inlet Gas Pressure (in. of water)
Maximum
10.5"
10.5"
Minimum
7"
7"
Dimensions, Inches (H x W x D)
Heater
23.5 x 18.5 x 8
23.5 x 25.9 x 8
Carton
25.8 x 21.3 x 10.1
25.8 x 28.7 x 10.1
Weight (pounds)
Heater
24
32
Shipping
29
38
SPECIFICATIONS
VN1800D
VN3000D
Btu (Variable)
6,600/12,000/18,000
6,600/18,000/30,000
Type Gas
Natural Only
Natural Only
Ignition
Piezo
Piezo
Pressure Regulator Setting
6" W.C.
6" W.C.
Inlet Gas Pressure (in. of water)
Maximum
10.5"
10.5"
Minimum
7"
7"
Dimensions, Inches (H x W x D)
Heater
23.5 x 18.5 x 8
23.5 x 25.9 x 8
Carton
25.8 x 21.3 x 10.1
25.8 x 28.7 x 10.1
Weight (pounds)
Heater
22
30
Shipping
27
36
Note
: Dimensions listed are outer most points on the heater (includes control
knobs and grill).
SERVICE
PUBLICATIONS
You can purchase a service manual from the address listed on the back page of this
manual. Send a check for $5.00 payable to DESA International.
SERVICE
HINTS
When gas pressure is too low
• pilot will not stay lit
• burner(s) will have delayed ignition
• heater will not produce specified heat
When gas quality is bad
• pilot will not stay lit
• burner(s) will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.