AIR FOR COMBUSTION 
AND VENTILATION
Continued
Figure 4 - Ventilation Air from Outdoors
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or 
ducts. You must provide two permanent openings: 
one within 12" of the ceiling and one within 12" 
of the floor. Connect these items directly to the 
outdoors or spaces open to the outdoors. These 
spaces include attics and crawl spaces. Follow the 
National Fuel Gas Code, ANSI Z223.1/NFPA 54, 
Section 5.3, Air for Combustion and Ventilation for 
required size of ventilation grills or ducts.
IMPORTANT:
 Do not provide openings for inlet 
or outlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic 
will activate the power vent.
INSTALLATION
 WARNING: A qualified ser-
vice person must install firebox. 
Follow all local codes.
 WARNING: Never install the 
firebox
•  in a bedroom or bathroom*
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing  or  other  flammable 
objects are less than 42 inches 
from the front, top or sides of 
the firebox
•  in high traffic areas
•  in windy or drafty areas
* Unless the installed log set is 
rated at 10,000 Btu/Hr or less.
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
  CAUTION:  Log  heaters  in-
stalled in this firebox create warm 
air currents. These currents move 
heat to wall surfaces next to fire-
box. Installing firebox next to vinyl 
or cloth wall coverings or operat-
ing firebox where impurities (such 
as,  but  not  limited  to,  tobacco 
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps, 
etc.) in the air exist, may discolor 
walls or cause odors.
IMPORTANT:
 Vent-free gas log heaters add mois-
ture to the air. Although this is beneficial, installing 
firebox in rooms without enough ventilation air may 
cause mildew to form from too much moisture. See 
Air for Combustion and Ventilation, page 7. 
IMPORTANT:
 Make sure the firebox is level. If 
firebox is not level, log set will not work properly. 
Note:
 Your firebox is designed to be used in zero 
clearance installations. Wall or framing material 
can be placed against any exterior surface on the 
rear, sides, top or bottom of your firebox, except 
where standoff spacers are integrally attached. If 
standoff spacers are attached to your firebox, these 
spacers can be placed directly against wall or fram-
ing materials. Use the dimensions shown for rough 
opening to create the easiest installation.
Use  dimensions  shown  for  rough  openings  to 
create the easiest installation (see Built-In Firebox 
Installation, page 11).
INSTALLATION CLEARANCES
  WARNING:  Maintain  the 
minimum clearances. If you can, 
provide greater clearances from 
floor, ceiling and adjoining wall.
Carefully  follow  these  instructions. This  will 
ensure safe installation.
Minimum Wall and Ceiling Clearances (see 
Figure 5, page 10)
A.  Clearances  from  the  side  of  the  fireplace 
cabinet to any combustible material and wall 
should follow diagram in Figure 5, page 10.
 
Example:
 The face of a mantel, bookshelf, 
etc.  is  made  of  combustible  material  and 
protrudes 3 
1
/
2
" from the wall. This combus-
tible material must be 4" from the side of the 
fireplace cabinet (see Figure 5, page 10).