Hoshizaki KM2000SWF3 Benutzerhandbuch

Seite von 56
39
15) Evacuate the system, and charge it with refrigerant.  See the Nameplate for the required
       refrigerant charge.
16) Connect the Terminals, and replace the Terminal Cover in its correct position.
17) Replace the panels in their correct positions.
18) Turn on the power supply.
4. REMOVAL AND REPLACEMENT OF DRIER
IMPORTANT
Always install a new Drier every time the sealed refrigeration system is opened.
Do not replace the Drier until after all other repair or replacement has been
made.
1) Turn off the power supply.
2) Remove the panels.
3) Recover the refrigerant and store it in an approved container.
4) Remove the Drier.
5) Install the new Drier, with the arrow on the Drier, in the direction of the refrigerant flow.
     Use nitrogen gas at the pressure of 3-4 PSIG when brazing the tubings.
6) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.
7) Evacuate the system, and charge it with refrigerant.  For water-cooled models, see the
     Nameplate  for the required refrigerant charge.  For remote air-cooled models, see the
     Charge Label in the machine compartment.
8) Replace the panels in their correct positions.
9) Turn on the power supply.