TROUBLESHOOTING
  WARNING: Turn off log set and let cool before 
servicing. Only a qualifi ed service person should 
service and repair log set.
POSSIBLE  CAUSE
REMEDY
OBSERVED PROBLEM
Note: All troubleshooting items are listed in order of operation.
1. Poor fuel quality
2.  Fireplace venting system not drafting 
properly
3.  Excessive flame impingement or 
blockage
4. Improper fuel/air mixture
5. Excessive gas supply/pressure
1.  Passage of air/gas across irregular sur-
faces
1.  Incorrect gas supply or pressure
2.  Blocked burner orifi ce or burner mani-
fold ports
3. Improper burner orifi ce size
Log set is smoking/sooting excessively
(Note: It is natural and unavoidable for
vented gas log sets to produce moderate
levels of carbon (soot) where fl ames 
contact the logs. This is especially true
with propane/LP gas.)
Burner is excessively noisy
(Note: The movement and combustion of 
gas will create low, unavoidable levels of 
noise.)
Burner fl ame is too low or too high
1.  Contact local natural or propane/LP gas 
company
2.  Adjust damper wide open and/or have 
fireplace and venting professionally 
cleaned and checked
3.  Separate the logs to allow more fl ame 
passage
4.  Remove any foreign items from the 
fl ame pattern and/or check for proper 
orifi ce sizing
5. Preheat fl ue in very cold weather
1.  Relieve any tight bends or kinks in gas 
supply line 
1.  Check for proper gas supply pressure
2.  Free burner orifi ce and manifold ports 
of any burrs, paint, or other blockage
3.  Verify proper burner orifi ce sizing (see 
Figure 2, page 4)
SERVICE HINTS
TROUBLESHOOTING
SERVICE HINTS
When Gas Pressure is Too Low
•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specifi ed heat
•  propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local 
propane/LP or natural gas supplier.