Enterasys 6000 Betriebsanweisung

Seite von 420
Configuring Frame  Relay
6-33
Frame Relay PVC Parameters
1 The DLCI must match the DLCI  configured  at the  remote end of the physical link.
2 Some formulae that might help in determining  these values  are:
B
C
  >= 8 times  maximum packet size.
B
E
 <=  B
C
 multiplied by [(line speed/CIR) minus 1].
Connection Priority
prioritizes this connection for intra-nodal traffic;  the higher the number, the higher the 
priority. (This priority has no effect on traffic exiting a node.)
A priority is also configured in Node Defaults, as well as for each logical port, SNA 
PU, LLC2 host, Bridge Port/LLC2 Interface, IP interface, IPX interface, and SVC 
subscriber. The device processor in the node uses these priorities to help determine the 
order in which it will process protocols.
When configuring priorities, be careful to consider the types of 
traffic being routed on other connections in the node.
Primary/Secondary Name
identifies each end of the connection to the console operator. The software does not 
use this information.
Primary/Secondary DLCI
is  a  logical connection identifier for  each  end of the  PVC.
Primary/Secondary LP
is the (FRX6000 only) RLP at each end of the internal connection.
Primary/Secondary Port
is the port at each end of the internal connection.
Table 6-7    Frame Relay PVC Parameters
Parameter
Valid Values
Default Value
Connecti on Priori ty
0–9
0
Primary/ Secondary Name
0–31 characters
none
Primary/ Secondary DLCI
16–991 
1
16
Primary/ Secondary LP
FRX4000, FRM:
 0 
FRX6000: 
0–7
0
Primary/ Secondary Port
0–7
0
Commi tted I nf. Rate 
(CIR)
0–2000
 (kbits/sec)
 
2
0
Commi tted Burst Size 
(BC)
½ CIR–5x  CIR (kbits) 
2
½ CIR
Excess Burst Size 
(BE)
0–2000 
(kbits) 
2
0