Enterasys 6000 Betriebsanweisung

Seite von 420
Configuring X.25
7-21
Type 
U
 followed (with no spaces) by the desired characters, 
1–9
A–C
, indicating 
which positions of the twelve digits in the original user data are to replace the 
selected portion of the packet.
If you are replacing called or calling address with original user data, 
all the  replacing  characters must be digits.  Also, the user data must be
specified in the template ID.
T
 
= Text (valid for replacement of user data only). Type 
T
 followed (with no spaces) 
by the text that will replace the user data.
Replacing Protocol ID
Press 
[E]
 at the Translation Template Maintenance Menu. When prompted, enter a 
string of up to four hex bytes.  If fewer  than four  bytes are entered, the remaining field 
is filled with zeroes.
Replacing Facilities
Press 
[F]
 at the Translation Template Maintenance Menu. When prompted, enter a 
string of up to 109 hex bytes.
Translation Examples
Example 1 – Replacing the first four digits of the called address with digits from the 
user data field:
Assume the Template ID is 
3110*U*
 and the called address field in the template is 
U1234X5
. A packet with called address 
31101234567890
 and user data 
5678
 is 
received. The packet matches Template ID 
3110*U*
; therefore, a translation 
occurs as follows:
U1234
 of 
U1234X5
 indicates that positions 1, 2, 3, and 4 of the user data of 
the received packet (
5678
) will replace the first four digits of the called 
address (
3110
).
X5
 of 
U1234X5
 takes the fifth position of the template (
*
)  and searches for  a 
match in the part of the original called address not yet translated 
(
1234567890
). (The match is found in the entire string 
1234567890
.)
The translated called address is 
56781234567890
.
Example 2 – Appending the subaddress from the user data to the called address:
Assume the Template ID is 
3110*U??
 and the called address field in the template 
is 
X12345U12
. A packet with called address 
311012345678
 and user data 
99
 is 
received. The packet matches Template ID 
3110*U??
; therefore, a  translation 
occurs as follows:
User data 
99
 from the packet is appended to the called address 
311012345678
.
The translated called address is 
31101234567899
.