9-10
FRX/FRM 3. 3 User G uide, Rev 04
Figure 9-4    BSC Batch Port Record, Screen 3
BSC Batch Port Parameters
Table 9-2    BSC Batch Port Parameters
Parameter
Valid Values
Default  Value
Port Type
BSC-B
(not valid here)
Physical Port Interface
see explanation
see explanation
Blocked Port Flag
Y/N
N
Line Speed
see explanation
9600
Retransmission Period
 (ms)
1–9999
2000
Maximum Retransmissions
1–99
5
Maximum Bytes per  Frame
25–4105
4105
Generate Clock
Y/N
Y
Rcv Clock (TT) from DTE
Y/N 
1
N
On-line Sys.  Memory  Changes
Y/N
N
EBCDIC
Y/N
Y
Tr ansparent Text Supported
Y/N
Y
Ack
A–C
none
Controll er Type
A–F
none
Full Duplex
Y/N
Y
# of  Beginning Sync Chars
2–10
2
# of Trai ling PAD Chars
1–10
1
No Response Ti mer (sec)
2–10
2
(continued on next  page)
Node Name=nod exyz
BSC  Batch  Sub scriber In formation
*
R LP: 0
Port: 1
*
I /O: V.35
A  Sq B Local  Su b.C  R emote S ub.D  Atcl
E R tytm
F R ty#G  Del
01 100101000000000200201000000000N
60
0
02 100101000000001211020100000000N
60
0
03 100101000000002212202010000000N
60
0
04 100101000000003203301000000000N
60
0
05 100101000000004231020100000000N
60
0
Select