Configuring Async Ports
10-11
Physical Port Interface
must be configured as follows. For reference, port locations are shown on  page 5-
(FRX4000), page 5-2 (FRX6000), and page 5-3 (FRM).
FRX4000 port 0 is always 
RS-232
.
FRX4000 port 1 is 
RS-232
 or 
DSU
, depending on whether the optional CSU/
DSU card is installed.
FRX4000 ports 2 and 3 are determined by the attached cables: RS-232, V.35, 
RS-449, or X.21.
FRX4000 ports 4–7 are determined by the expansion Line Interface Card (LIC) 
and attached I/O cables. Line Processor Configuration identifies the LIC, and 
only the valid interfaces will be displayed on the Port screen. Possible interfaces 
are
 
RS-232, V.35, RS-449, and X.21. (RS-449 and X.21 interfaces require an 
RS-422 LIC, which is available by special order.)
FRX6000 ports 0–7 on each RLP are determined by the Line Interface Card(s) 
and attached I/O cables. Line Processor Configuration identifies the LIC, and 
only the valid interfaces will be displayed on the Port screen. Possible interfaces 
are
 
RS-232, V.35, RS-449, and X.21
. (RS-449, RS-530, and X.21 i
nterfaces 
require an RS-422 LIC.)
FRM ports 0–7 are determined by the Line Interface Cards and attached I/O 
cables. Line Processor Configuration identifies the LICs, and only the valid 
interfaces will be displayed on the Port screen
Possible interfaces  are
 
RS-232, 
V.35, RS-449, and X.21
. (RS-449, RS-530, and X.21 i
nterfaces require an RS-422 
LIC. Also, RS-530 and X.21 are available through special order only.)
Blocked Port Flag
will cause the port to be enabled (
N
) or disabled (
Y
) at node IPL. The port will remain 
in that state until this parameter is changed or an on-line enable (
[B], [B],  [C]
 from the 
Main Menu) or disable (
[B], [B], [A]
 from the Main Menu) is performed.
X.3 Line Speed
is the data transmission rate in bits per second. Specify the line speed that matches (as 
closely  as  possible) the configuration of the device  connected  to the  port.
Selecting this item displays a list of valid line speeds. To specify a speed, press the 
letter corresponding  to the speeds.  Valid speeds are:
50
75
75/1200
100
110
134.5
150
200
300
600
1200
1800
2400
4800
9600
19.2K
38.4K
57.6K
Autobaud
Selecting 
Autobaud 
causes the line speed to be read from the first trans-
mission from the async device, then set automatically.
Initial Profile Name
is an async PAD profile (described on page 10-2) that will be in effect on this port until 
the user of the async device logs into the PAD, at which time the profile in the PAD 
Logins record (described on page 10-7) becomes effective.  (If 
N
 is selected in the Port 
record for 
Login Required
, the profile in the Port record is always in effect.) If the spec-
ified profile is not defined in the database, the default profile, 
90