Enterasys 6000 Betriebsanweisung
Configuring IP
11-5
IP Interface Parameters
Explanations of most parameters follow the table.
1
These addresses must also be configured in Subscriber records (described in Chapter 7),
and cannot contain wildcards. In the record for the Source Subscriber, do not configure
any Routing Path. In the record for the Destination Subscriber, configure
and cannot contain wildcards. In the record for the Source Subscriber, do not configure
any Routing Path. In the record for the Destination Subscriber, configure
1st Routing
Path
as the node, LP, and X.25 port that will be used for the physical interface. (On an
FRX6000, that LP does not need to be the same one that has IP installed.)
2
If the port is frame relay, make sure it is not configured (in the Port record) for backup
use only. (See Chapter 6.)
use only. (See Chapter 6.)
3
Make sure the DLCI is not part of a frame relay DLCI backup group or intra-nodal frame
relay PVC (both described in Chapter 6).
relay PVC (both described in Chapter 6).
Maximum Transmission Unit
is the maximum size (in bytes) of the data field that can be used to encapsulate an IP
datagram for transmission over the interface. Any datagrams larger than the
datagram for transmission over the interface. Any datagrams larger than the
Maximum
Transmission Unit
will be fragmented, resulting in additional processing on any inter-
Table 11-2 IP Interface Parameters
Parameter
Valid Values
Default Value
Maximum Transmission Unit
Ethernet: 1–1500
Other:
Other:
1–4096
1500
4096
4096
Network Mask
valid IP address
255. 0.0.0
Routing Metric Count
0–255
0
ICMP Redirects
Y/ N
Y
RI P Flash Updates
(sec)
0–300
30
RI P Full Updates
(sec)
0–300
60
Priority
0–9
5
Bandw idth All ocation G roup
1–16
1
Interface Type
X. 25, Ethernet, FRM
(frame
relay
, 802.3, 802.5
FRL
Source IP Address
valid IP address
0. 0.0.0
Destination IP Address
valid IP address
0. 0.0.0
Broadcast Address
valid IP address
0. 0.0.0
LAN Card Number
FRX4000, FRM:
0
FRX6000:
0–1
0
Source Subscriber
valid subscriber address
1
none
Destination Subscri ber
valid subscriber address
1
none
SVC Retry Timer
(sec)
5–60
20
SVC Idl e Timer
(min)
0–5
1
Max VCs to Establish
1–8
1
PVC Connection
Y/ N
N
Source Card
FRX4000, FRM:
0
FRX6000:
0–7
0
Source Port
0–7
2
0
Source DLCI
16–991
3
16