Enterasys 6000 Betriebsanweisung

Seite von 420
Syst em Events
18-5
Event Messages
A list of event messages follows, with each message's meaning and any action to be 
taken. The  list  is  modified as  necessary to include additional events. As shown in the 
example  under “Displaying Events"  (on page  18-3),  each message is  preceded by  the 
LP (FRX6000, FRM only) and port numbers.
If the recommended action does not correct a problem, contact Cabletron Systems 
Technical Support at:
Phone:
603-332-9400
  Monday–Friday, 8 AM–8 PM Eastern time
E-mail:
support@ctron.com
FTP:
ctron.com
 (
134.141.197.25
)
Login:anonymous
Password:Your e-mail  address
Messages:
198.
SABM/DISC with  wrong  link  address
Severity:
4
Meaning:
The HDLC frame processor task for the port has received an 
improperly addressed frame from the subscriber. This situation 
usually occurs when the port and subscriber devices are both con-
figured as logical DCEs or logical DTEs.
Action:
Modify the Port record so that one end  of the connection  is a logical 
DCE and the other is a logical DTE.
219.
Illegal TC/Gen Clk Combination
Severity:
1
Meaning:
The software has determined that a port is set to run at an illegal line 
speed (throughput class).
Action:
This is probably a configuration error. Check the Port record and 
change the throughput class, if necessary.
250.
Excessively noisy line
Severity:
3
Meaning:
Self-explanatory.
Action:
Check the communications line and cables.
304.
LP Buf  Usage exceeded T:“n”  C:“n”
Severity:
4
Meaning:
The LP statistic
 Percentage of Buffers in Use
 has exceeded the 
threshold (
T:“n”
) that was set by the user. (
C:“n”
 is the current 
value.)
Action:
If this happens frequently, you may need to reroute some traffic.