Enterasys 6000 Betriebsanweisung

Seite von 420
Configuring Frame  Relay
6-13
Figure 6-7    Frame Relay DLCI Configuration Screen 2
If you configure a 
Backup Group  Number
Enable Backup Protocol
 will be 
replaced by several parameters (listed in Table 6-3 on page 6-15) that 
determine backup operation.
If you change
 
Enable Backup Protocol 
to 
Y
, the
 Backup Group Number 
entry 
will disappear.
Viewing Learned DLCIs (Figure 6-4, Item E)
If the port is a logical DTE, a list of all DLCIs (extracted from LMI/AnnexD frames) 
can be displayed by pressing
 [E]
 at Figure 6-4. Each displayed DLCI will be followed 
by three columns:—
A
N
, and 
C
—with the following possible values:
A
:
a
 = active, 
I
 = inactive.
N
:
n
 = new, 
o
 = old. (A newly learned DLCI will become "old" after the first 
Full Status Inquiry. 
C
:
c
 = configured on the node, 
1
 =  not  configured.
Nod e Name=n ode_xyz
Frame  Relay  DLC I C onfiguration  (s creen  2  of 2)
*
LP
0
*
Port
7
*
DLCI
16
A Back up Grou p N umber
0
B Enable Backu p Protocol
N
Option: