Enterasys csx400 Betriebsanweisung
FRACTIONAL E1 CONFIGURATION USING PPP
Local Management User’s Guide
B-9
WPIM-E1 Physical Configuration
Begin the WPIM-E1 configuration by accessing the WAN Physical Configuration screen through
Local Management (
Local Management (
). Proceed with the following steps:
1.
Use the arrow keys to highlight the [WPIM] field at the bottom of the screen. Press the
SPACEBAR to toggle the field to the WPIM being configured, then press ENTER.
SPACEBAR to toggle the field to the WPIM being configured, then press ENTER.
2.
Use the arrow keys to highlight the MgrType. Press the SPACE bar to select PPP, then press
ENTER.
ENTER.
3.
Use the arrow keys to highlight Timeslot View. Press the SPACEBAR to select New, then
press ENTER. The cursor moves to Timeslot #2 of the Timeslot Configuration Table.
press ENTER. The cursor moves to Timeslot #2 of the Timeslot Configuration Table.
4.
Insert an interface number (see NOTE below) into every timeslot being used (in the example
shown in
shown in
number, press ENTER, then use the arrow keys to highlight the next timeslot field. Exit this
field by using the arrow keys.The cursor automatically moves to the E1 Line Coding field.
field by using the arrow keys.The cursor automatically moves to the E1 Line Coding field.
5.
Use the arrow keys to highlight E1 Line Coding. Press the SPACEBAR to select HDB3 or
AMI.
AMI.
6.
Use the arrow keys to highlight E1 Frame Type. Press the SPACEBAR to select E1 or
E1-CRC.
E1-CRC.
7.
Use the arrow keys to highlight E1 Tx Clock Source. Press the SPACEBAR to select Local
(no clock source provided by telephone company) or Loop (clock source provided by telephone
company).
(no clock source provided by telephone company) or Loop (clock source provided by telephone
company).
8.
Use the arrow keys to highlight the SAVE command, then press ENTER. The message “Save
Done!” displays and Local Management saves the changes to memory. The host platform
reboots. For further configuration, the Local Management connection must be re-accessed.
Done!” displays and Local Management saves the changes to memory. The host platform
reboots. For further configuration, the Local Management connection must be re-accessed.
NOTE
The value assigned to the timeslots is the interface being used for WAN
communication. The next available interface is displayed on the WAN Physical
Configuration screen (see
communication. The next available interface is displayed on the WAN Physical
Configuration screen (see
The following three steps are based on information supplied by the service provider.
Consult the service provider for the correct settings.
Consult the service provider for the correct settings.
!
CAUTION
If you are using a Local clock source, set only one end of the circuit for Local, the other
end must be set for Loop.
end must be set for Loop.