Enterasys csx400 Betriebsanweisung

Seite von 194
Bridge Setup Screen
Local Management User’s Guide
1-31
Selecting the Bridge Port Pair Administrative Status
To select the bridge port pair administrative status, perform the following steps:
1.
Use the arrow keys to highlight the [BRIDGE_PORT XX] field at the bottom of the Bridge 
Setup screen.
2.
Press the SPACE bar or BACKSPACE to select the bridge port you want to configure. The 
selected bridge port displays in the Bridge Port Pair Admin Status field.
3.
Use the arrow keys to highlight the BRIDGE PORT PAIR ADMIN STATUS: PORT X - -> 
PORT [Y] 
field.
4.
Press the SPACE bar or BACKSPACE to select the port you want to enable or disable bridge 
traffic.
5.
Use the arrow keys to highlight the BRIDGE PORT PAIR ADMIN STATUS: PORT X - -> 
PORT [Y] [ENABLED] 
field.
6.
Press the SPACE bar or BACKSPACE to select ENABLE or DISABLE.
For example, the following bridge setup indicates that bridge port 01 is configured NOT to 
bridge traffic to bridge port 02:
BRIDGE PORT PAIR ADMIN STATUS: PORT 01 - - > PORT [02] [DISABLED]
7.
Use the arrow keys to highlight the SAVE command field.
8.
Press ENTER. The Event Message field at the top of the screen displays “SAVED OK”.