Enterasys 2200 Betriebsanweisung

Seite von 330
VLAN Switch Operation
VLAN Operation and Network Applications
12-9
12.7.1 Receiving Frames from VLAN Ports
When a switch is placed in 802.1Q Operational Mode, every frame received by the switch must 
belong, or be assigned, to a VLAN.
Untagged Frames
The switch receives a frame from Port 1 and examines the frame. The switch notices that this 
frame does not currently have a VLAN tag. The switch recognizes that Port 1 is a member of 
VLAN A and classifies the frame as such. In this fashion, all untagged frames entering a VLAN 
switch assume membership in a VLAN. 
The switch will now make a forwarding decision on the frame, as described in 
.
Tagged Frames
In this example, the switch receives a tagged frame from Port 4. The switch examines the frame 
and notices the frame is tagged for VLAN C. This frame may have already been through a 
VLAN-aware switch, or originated from a station capable of specifying a VLAN membership. If a 
switch receives a frame containing a tag, the switch will classify the frame in regard to its tag 
rather than the PVID for its port. 
The switch will now make a forwarding decision on the frame, as described in 
.
12.7.2 Forwarding Decisions
The type of frame under consideration and the filter setting of a VLAN switch determines how it 
forwards VLAN frames.
12.7.2.1 Broadcasts, Multicasts, and Unknown Unicasts
If a frame with a broadcast, multicast, or other unknown address is received by an 802.1Q 
VLAN-aware switch, the switch checks the VLAN classification of the frame. The switch then 
forwards the frame out all ports that are identified in the Forwarding List for that VLAN. For 
example, if Port 3, shown in 
, received the frame, the frame would then be sent to all 
ports that had VLAN C in their Port VLAN List.
NOTE: A VLAN ID is always assigned to a port. By default, it is the Default VLAN (VLAN 
ID = 1).