Printronix l7032 Verweishandbuch

Seite von 416
 106
Chapter
2
Command Codes
Interrupt
Purpose
In cases where a single command sequence exceeds the buffer 
capacity, an interrupt can be used to break the command 
sequence and specify the position where the sequence begins 
printing again.
Mode
Graphics with or without an Extended Graphics Command 
selected
Format
(cc) I 
dis (cc)-
(cc)
Represents the Special Function Control Code 
(SFCC). Enter the specific SFCC for your VGL 
configuration.
I
Specifies the Interrupt command. Enter I.
dis
Normal Resolution:
Defines the interrupt position in tenth inches and 
dot columns. Enter a two-digit interrupt position 
value ranging from 00 through 99 to define a 
position of 0.0 through 9.9 inches and a third digit 
ranging from 0 through 9 to specify 0 through 9 
additional dot columns. VGL automatically 
understands the decimal between the first and 
second digits for tenth inches and automatically 
interprets the third digit as dot columns. For 
example, entering 126 specifies a 1.2-inch plus 6-
dot column interrupt position. Setting the interrupt 
position parameter to all zeros processes all data in 
the VGL buffer before the next sequence is 
initiated.
High Resolution:
Defines the interrupt position in thousandth inches. 
Enter a five-digit vertical value ranging from 00000 
through 99999 to define a vertical justification of 
0.000 inch through 99.999 inches. VGL 
automatically understands the decimal between the 
second and third digits. 
(cc)-
Graphics Mode CR used as a command terminator. 
Enter the SFCC for your VGL configuration immedi-
ately followed by to end the command sequence. 
NOTE: Only required outside of an Extended 
Graphics sequence.