Printronix l7032 Verweishandbuch
PDF417
249
PDF417 Command Format
Default Ratio:
(cc)
dir p type [X[D]n] [Y[D]n] [(Hn)] (Wn)] [Ah:w]
[R
n] [Cn] [Sn], DATA^G
(cc)
Represents the Special Function Control Code
(SFCC). Enter the specific SFCC for your VGL
configuration.
(SFCC). Enter the specific SFCC for your VGL
configuration.
dir
Represents the direction of the bar code. Enter B
for horizontal or C for vertical bar codes.
for horizontal or C for vertical bar codes.
p
An optional readable data field. Enter N so no
readable data prints in this field.
readable data prints in this field.
type
Enter & for PDF417.
X[D]
n
Optional parameter to designate the width of the
narrow element in either the default 60 X 72 dots
per inch or, if the D is given, in target dots. The
default size is 1/60th of an inch.
narrow element in either the default 60 X 72 dots
per inch or, if the D is given, in target dots. The
default size is 1/60th of an inch.
Y[D]
n
Optional parameter to designate the height of the
bar code in either the default 60 X 72 dots per inch
or, if the D is given, in target dots. The default size
is 2/72nd of an inch.
bar code in either the default 60 X 72 dots per inch
or, if the D is given, in target dots. The default size
is 2/72nd of an inch.
H
n
Optional parameter to adjust the overall height of
the bar code symbol (including human readable
data). Height adjustments are made in 0.1-inch
increments; enter H and a value from 4 through 99
to select height adjustments from 0.4 through 9.9
inches. Parameters W
the bar code symbol (including human readable
data). Height adjustments are made in 0.1-inch
increments; enter H and a value from 4 through 99
to select height adjustments from 0.4 through 9.9
inches. Parameters W
n, Rn, Cn or A cannot be
entered if this parameter is used.
W
n
Optional parameter to adjust the maximum width of
the symbol based on the narrow element width.
Enter W
the symbol based on the narrow element width.
Enter W
n; where n is the overall width in tenths of
an inch. Parameters H
n, Rn, Cn or A cannot be
entered if this parameter is used.
A
h:w
Optional parameter for specifying the symbol
height-to-width ratio where
height-to-width ratio where
h is the height and w is
the width, both expressed as integers. The default
is 1:2. Parameters H
is 1:2. Parameters H
n, Wn, Rn, or Cn cannot be
entered if this parameter is used.
R
n
Optional parameter that specifies the number of
rows the symbol will have. Enter R followed by the
number of rows in the range of 3 through 90 in
multiples of 3. Parameters H
rows the symbol will have. Enter R followed by the
number of rows in the range of 3 through 90 in
multiples of 3. Parameters H
n, Wn, Cn or A cannot
be entered if this parameter is used.
C
n
Optional parameter that specifies the number of
columns the symbol will have. Enter C followed by
the number of columns in the range of 1 through
90. Parameters H
columns the symbol will have. Enter C followed by
the number of columns in the range of 1 through
90. Parameters H
n, Wn, Rn or A cannot be entered