Printronix l7032 Verweishandbuch

Seite von 416
PDF417
 249
PDF417 Command Format
Default Ratio:
(cc) 
dir p type [X[D]n] [Y[D]n] [(Hn)] (Wn)] [Ah:w] 
[R
n] [Cn] [Sn], DATA^G
(cc)
Represents the Special Function Control Code 
(SFCC). Enter the specific SFCC for your VGL 
configuration.
dir
Represents the direction of the bar code. Enter 
for horizontal or C for vertical bar codes.
p
An optional readable data field. Enter N so no 
readable data prints in this field.
type
Enter & for PDF417.
X[D]
n
Optional parameter to designate the width of the 
narrow element in either the default 60 X 72 dots 
per inch or, if the D is given, in target dots. The 
default size is 1/60th of an inch.
Y[D]
n
Optional parameter to designate the height of the 
bar code in either the default 60 X 72 dots per inch 
or, if the D is given, in target dots. The default size 
is 2/72nd of an inch.
H
n
Optional parameter to adjust the overall height of 
the bar code symbol (including human readable 
data). Height adjustments are made in 0.1-inch 
increments; enter H and a value from 4 through 99 
to select height adjustments from 0.4 through 9.9 
inches. Parameters W
n, Rn, Cn or A cannot be 
entered if this parameter is used.
W
n
Optional parameter to adjust the maximum width of 
the symbol based on the narrow element width. 
Enter W
n; where n is the overall width in tenths of 
an inch. Parameters H
n, Rn, Cn or A cannot be 
entered if this parameter is used.
A
h:w
Optional parameter for specifying the symbol 
height-to-width ratio where 
h is the height and w is 
the width, both expressed as integers. The default 
is 1:2. Parameters H
n, Wn, Rn, or Cn cannot be 
entered if this parameter is used.
R
n
Optional parameter that specifies the number of 
rows the symbol will have. Enter R followed by the 
number of rows in the range of 3 through 90 in 
multiples of 3. Parameters H
n, Wn, Cn or A cannot 
be entered if this parameter is used.
C
n
Optional parameter that specifies the number of 
columns the symbol will have. Enter C followed by 
the number of columns in the range of 1 through 
90. Parameters H
n, Wn, Rn or A cannot be entered 
if this parameter is used.