Printronix l7032 Verweishandbuch

Seite von 416
Planet
 253
Quiet Zone
The bar code structure requires a completely blank quiet zone which extends 
4.75 inches from the right edge of the mail piece. In addition, a minimum quiet 
zone of 0.040-inch above and below the bar code data must also be provided. 
You must provide sufficient space for this zone.
Start/Stop Code
The start and stop codes are referred to as “framing bars” in Planet. The start 
and stop codes are each one tall bar, one identifying the leading and trailing 
end of the bar code. The start/stop code is automatically produced with each 
bar code. The start/stop code structure permits bar code scanning in a left-to 
right direction only.
Data Field
The bar code data produces a single field of 60 bars for an 11-digit data field. 
The bars are grouped in sets of five. Each set of five bars (comprised of three 
tall bars and two short bars) represents one of the five digits of the zip code, 
plus the four-digit zip code extension. If the Delivery Point Bar Code is used, 
an additional two-digit code is also added to make an 11-digit data field.
Exact bar code dimensions depend on the type of printer used, but fall within 
the following specifications:
Each bar width is equal and is .020-inch ± .005-inch. Each bar height is either 
a tall (full) or short (half) bar, representing a 1 or 0, respectively. Each tall bar 
is .125-inch ± .010-inch; each short bar is .050-inch ± .010-inch. Horizontal 
spacing between bars (pitch) is 22 bars ±
 
2 bars per inch over any 0.50-inch 
portion of the bar code. Horizontal spacing at 24 and 20 bars per inch is 
0.0416-inch and .050-inch, respectively, with a clear vertical space ranging 
from 0.012-inch to 0.040-inch between bars.
Check Digit
The twelfth digit represents the automatic check digit character. The Mod 10 
check digit is added automatically to verify accurate scanning.