Printronix l7032 Verweishandbuch

Seite von 416
 280
Chapter
3
Bar Codes
UPC-A Command Format
NOTE: See page 164 for the IBARC, command format and definitions.
Default Ratio:
(cc) 
dir p type data (cc)G
Variable Ratio:
(cc) 
dir p [9] [:] type [ratio] data (cc)G
(cc)
Represents the Special Function Control Code 
(SFCC). Enter the specific SFCC for your VGL 
configuration.
dir
Represents the direction of the bar code. Enter B 
for horizontal bar codes; enter C for vertical bar 
codes.
p
Prints the optional readable data field. The 
readable data field is printed below a horizontal bar 
code or on the left-hand side of a vertical bar code.
Replace 
p in the bar code command with one of the 
codes listed in Table 61 to print the readable data 
field in the corresponding font with the specified 
guard band gap.
NOTE: For UPC 100% PDF is printed in 12 cpi Letter Gothic. For UPC 80% it 
is printed in 15 cpi Letter Gothic.
9 or :
Selects the variable ratio length bar code feature, 
which permits unique bar and space width ratios 
adjusted for specific applications. 
Enter the number 9 to select variable ratio bar 
codes represented in line matrix printer dots (60 x 
72 dpi).
Enter : to select variable ratio bar codes 
represented in actual printer dots (203 x 203 dpi or 
300 x 300 dpi, depending on the printer head being 
used).
Table 61. Printable Data Field Fonts
Font
Gap
p code
Standard 10 cpi
3 dots
Y
OCR-A
3 dots
O
OCR-A
.1-inch
S
OCR-B
3 dots
B
OCR-B
.1-inch
T
None
N