Printronix P7000 Benutzerhandbuch

Seite von 210
 178
Appendix C
Operation
Set The Tear Bar Distance
To set the tear bar distance, do the following steps:
1.
Make sure the printer is offline.
2.
Press the right arrow 
 until “OFFLINE/ZTP SETTINGS” displays.
3.
Press the down arrow 
. “ZTP DataTime” displays.
4.
Press the right arrow 
 until “ZTP TearDist” displays.
5.
Press the down arrow 
. “ZTP TearDist/xx/144 Inch” displays.
6.
Press the Enter key. A scale prints to indicate the tear bar distance in 
relation to the tear bar.
7.
Press the left arrow 
 or right arrow 
 to decrease or increase the tear 
bar distance in increments of 1/144th of an inch.
8.
Press Enter to select the desired value. An asterisk appears next the 
selected value.
9.
Press Enter again to print a new scale. For correct tear bar distance, the 
zero should align with the tear bar. See Figure 31.
Figure 31. Correct Tear Bar Distance
NOTE: When a new ZTP Tear Bar Dist value is selected, the printer will lose 
the current print position until you reset the top of form to 
automatically save the new value.
10. Reset the top of form using the procedure on page 179.
+50 
-50 
Print Station
Correct 
TearBar 
Distance 
Physical TearBar 
Position