Printronix SL5000e Benutzerhandbuch

Seite von 398
106
Chapter
3
QUICK SETUP
Gap/Mark Sensor
The available options specify the sensor type needed for detecting the Top-of-
Form position on media with label length indicators (gaps, notches, holes, or 
black marks).
Disable. Select when using media with no label length indicators (no 
gaps, notches, holes, or black marks), or
 when you want the printer to 
ignore all existing label length indicators on the installed media.
NOTE: When you select Disable, the length of each label is based on the 
Label Length value entered in the QUICK SETUP or MEDIA 
CONTROL menu or the value sent via host software.
Mark. Select when using media that has horizontal black marks located 
on the underside of the label liner or tag stock. The Top-of-Form position 
is the leading edge of the black mark.
Gap. Select
 when using media with a liner space between die-cut labels 
or when using tag stock with notches or holes as label length indicators 
on white background media. The Top-of-Form position is the leading 
edge of the die cut label (trailing edge of the gap, notch, or hole).
Advanced Gap. Select when using media that has liner gaps between 
die cut labels with black background. The Top-of-Form position is the 
leading edge of the die cut label (trailing edge of the gap, notch, or hole).
Advanced Notch. Select when using media with notches or holes that 
interrupt a black vertical line on the underside of the media. The Top-of-
Form position is the leading edge of the die cut label (trailing edge of the 
gap, notch, or hole).
The factory default is Disable.
Auto Calibrate
This feature is used to improve the sensitivity and reliability of the Media 
Sensor in detecting gaps, notches, holes, or black marks on the installed 
media, as well as a paper out condition.
Auto Calibrate can also be initiated from the TEST PRINT key, the 
CALIBRATE CTRL menu, or the DIAGNOSTIC menu. Press the 
 key with 
“Auto Calibrate” displayed. The printer will then advance media the distance 
needed to accurately detect the label length indicators, then stop at the Top-
of-Form position and momentarily display the Sensed Distance. The process 
takes a few seconds to complete. The end result will be a change to the Gap/
Mark Threshold, Paper Out Threshold, and Sensed Distance values that the 
printer will use. The changes in values take effect immediately within the 
current configuration menu.
Auto Calibrate is completed successfully when the Sensed Distance 
displayed correctly matches that of the installed media. When Gap is 
selected, the Sensed Distance should match the length from the trailing edge 
of one gap to the trailing edge of the next gap (one label + one gap). When 
Mark is selected, the Sensed Distance should match the length from the 
leading edge of one black mark to the leading edge of the next black mark.
Auto Calibrate supports label lengths up to 24 inches.