Appendix A  Loading Revised Firmware
Using Firmware Cartridges
Quantum DAT 160 User’s Guide
52
Using Firmware Cartridges
1
The following procedure describes how to upgrade the tape drive 
firmware using a firmware upgrade tape cartridge. Firmware upgrade 
cartridges are available only to qualified Quantum OEM customers. 
Contact your sales representative for information. 
1
Power on the host system with the DAT 160 drive installed.
2
Close all applications that might try to communicate with the drive 
during the firmware upgrade procedure.
3
Insert the firmware upgrade cartridge. The drive automatically 
recognizes the firmware upgrade cartridge and begins downloading 
the firmware from the cartridge into DRAM. When the firmware has 
been downloaded into DRAM, the drive ejects the firmware upgrade 
cartridge and the drive LEDs blink in a progressive pattern. When the 
blinking pattern stops, the firmware upgrade operation is complete.
4
It may be necessary to reboot the system to ensure that your backup 
software application continues to recognize the tape drive.
Note:
The firmware can also be upgraded from a host computer via 
the SCSI connection using software available at 
www.quantum.com
.
Warning:
Once the firmware upgrade cartridge is inserted into 
the drive, no power interruption can occur while the 
firmware is loading. Do not power off the drive. If a 
power interruption occurs, the firmware may not be 
loaded correctly and the drive may not operate 
properly. 
 
Do not power down the host system or disconnect 
power to the drive until the drive LEDs stop flashing. 
Otherwise, the drive may be rendered inoperative.