Quantum acl 4 Installationsanweisungen

Seite von 68
 Appendix B Supplemental Installation Procedures
Loading the Library with Cartridges
ACL 4/52 Facilities Planning and Installation Guide
39
Loading the Library with Cartridges
2
Note:
The “Auto-Load” feature must be “Enabled” before performing this 
procedure. If this feature is not currently Enabled, refer to 
“Enabling/Disabling the Auto-Load Feature” on page 36.
Caution:
Examine all cartridges before loading them into the library 
or tape drive. Look for label stock or other foreign material 
that may be clinging to the cartridges.
1
With the SDA displaying 
System On-line
, press and release the 
load port OPEN
 button and verify that the indicator begins 
blinking. (After several seconds, the load port door will 
automatically open.)
Warning:
Mechanical hazards could be exposed when the load port is 
partially open or closed. Do not attempt to insert hands or 
fingers into the load port opening at any time.
2
With the load port door open, place up to four cartridges in the 
available load port bins. 
3
Press and release the 
load port CLOSE
 button.
Warning:
The load port door is LOCKED in the “open” position. You 
must press and release the CLOSE button before 
attempting to close the load port door.
4
When the 
CLOSE
 Indicator (LED at the upper left corner of 
CLOSE
 button) is steadily lit, push the Load Port door closed. (The 
library will lock the door.)
5
Repeat Steps 1 through 4 until you have loaded a maximum of 48 
DLT™ cartridges into the library.