Quantum acl 4 Installationsanweisungen
Appendix B Supplemental Installation Procedures
Loading the Library with Cartridges
ACL 4/52 Facilities Planning and Installation Guide
39
Loading the Library with Cartridges
2
Note:
The “Auto-Load” feature must be “Enabled” before performing this
procedure. If this feature is not currently Enabled, refer to
“Enabling/Disabling the Auto-Load Feature” on page 36.
procedure. If this feature is not currently Enabled, refer to
“Enabling/Disabling the Auto-Load Feature” on page 36.
Caution:
Examine all cartridges before loading them into the library
or tape drive. Look for label stock or other foreign material
that may be clinging to the cartridges.
or tape drive. Look for label stock or other foreign material
that may be clinging to the cartridges.
1
With the SDA displaying
System On-line
, press and release the
load port OPEN
button and verify that the indicator begins
blinking. (After several seconds, the load port door will
automatically open.)
automatically open.)
Warning:
Mechanical hazards could be exposed when the load port is
partially open or closed. Do not attempt to insert hands or
fingers into the load port opening at any time.
partially open or closed. Do not attempt to insert hands or
fingers into the load port opening at any time.
2
With the load port door open, place up to four cartridges in the
available load port bins.
available load port bins.
3
Press and release the
load port CLOSE
button.
Warning:
The load port door is LOCKED in the “open” position. You
must press and release the CLOSE button before
attempting to close the load port door.
must press and release the CLOSE button before
attempting to close the load port door.
4
When the
CLOSE
Indicator (LED at the upper left corner of
CLOSE
button) is steadily lit, push the Load Port door closed. (The
library will lock the door.)
5
Repeat Steps 1 through 4 until you have loaded a maximum of 48
DLT™ cartridges into the library.
DLT™ cartridges into the library.