Quantum scalar 100 Betriebsanweisung
page 142
Fibre Channel MAP
Fibre Channel MAP
These steps are performed if
•
The Fibre Channel interface reports a reset or system error
•
The Fibre Channel interface reports an error processing a request or response
•
The Fibre Channel interface reports an excess of 10 LIPs in a 10-minute interval
•
Other Fibre Channel errors reported
•
FC connection LED is off
Verify Fibre Channel Connections
1.
Connect the service terminal to the Service Port.
•
2.
Press the Enter key on the service terminal.
•
If the prompt is not displayed, go to “Service Port MAP” on page 152. To
determine whether the RS-232 cable and service terminal are working properly.
determine whether the RS-232 cable and service terminal are working properly.
3.
From the service terminal, enter the
showBox
command.
•
4.
Confirm that the Fibre Channel connections are correctly displayed. If
showBox
displays the Fibre Channel connections correctly, go to “Examine Cables” below.
5.
If the Fibre Channel connections do not display correctly in the
showBox
display,
remove the GBIC and replace it with a known-good GBIC.
•
•
Proceed through “Replacing the GBIC” on page 154.
Test GBIC
Attention: You must stop I/O at the Fibre Channel host.
1.
With the known-good GBIC installed, confirm that the SNC’s Fibre Channel
connections are correctly displayed by issuing the
connections are correctly displayed by issuing the
showBox
command from the
service terminal.
•
If
showBox
displays the Fibre Channels correctly, exit this MAP.
2.
If the output of the
showBox
command still does not match the Fibre Channel
configuration, remove the known-good GBIC and reinstall the original GBIC.