Quantum scalar 100 Betriebsanweisung

Seite von 286
page 142
Fibre Channel MAP
Fibre Channel MAP
These steps are performed if 
The Fibre Channel interface reports a reset or system error
The Fibre Channel interface reports an error processing a request or response
The Fibre Channel interface reports an excess of 10 LIPs in a 10-minute interval
Other Fibre Channel errors reported
FC connection LED is off
Verify Fibre Channel Connections
1.
Connect the service terminal to the Service Port. 
2.
Press the Enter key on the service terminal. 
If the prompt is not displayed, go to “Service Port MAP” on page 152. To 
determine whether the RS-232 cable and service terminal are working properly.
3.
From the service terminal, enter the 
showBox
 command.
4.
Confirm that the Fibre Channel connections are correctly displayed. If 
showBox
 
displays the Fibre Channel connections correctly, go to “Examine Cables” below.
5.
If the Fibre Channel connections do not display correctly in the 
showBox
 display, 
remove the GBIC and replace it with a known-good GBIC. 
Test GBIC
Attention: You must stop I/O at the Fibre Channel host.
1.
With the known-good GBIC installed, confirm that the SNC’s Fibre Channel 
connections are correctly displayed by issuing the 
showBox
 command from the 
service terminal. 
If 
showBox
 displays the Fibre Channels correctly, exit this MAP. 
2.
If the output of the 
showBox
 command still does not match the Fibre Channel 
configuration, remove the known-good GBIC and reinstall the original GBIC.