Champion dh-1000 Техническое Руководство

Seite von 2
WASH PUMP 1H
P
Front View
5" [127]
15-3/8" [390]
3
3
8-5/8" [220]
3" [76]
2
2
5-3/4" [145]
1
11-5/8" [295]
1
4" [101] MINIMUM CLEARANCE
FRONT
20-1/4"[514]
INSIDE TRACKS
67"[1702]
HEIGHT
LOAD
HEIGHT
MACH.
DOORS
UP
34"[864]
CLEARANCE
75"[1905]
17"[432]
REMOVAL
84"[2134]
DOOR
9-1/2" [241]
3
Side View
58-1/2"[1485]
2
60-1/2" [1536]
1
25-1/4" [642]
25-7/8" [657]
Plan View
2-7/8"
[73]
1-1/8"
2-1/8"
7-1/4"
1-1/4" ROLL
20-7/8"
24-1/4" 
plan View
Side View
front View
typical table construction
Door-type
High Temperature
Dishwashing Machine
DH-1000
DH-1000 
D
oor
-type 
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. 
‘USGBC’ and related logo is a trademark owned by the U.S. Green Building Council and is used by permission.
Champion Industries, Inc., P.O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
Dimensions shown in inches
Warning: Plumbing and electrical connection 
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary and 
safety codes and the National Electrical Code.
Plumbing Notes: Because of the variation in
house-supplied water, a pressure regulating valve 
(PRV) for incoming water supply is needed. The
PRV can be purchased from Champion or obtained
locally. It is also recommended that a pressure
gauge 0-60 psi (supplied by others) be installed in 
the water supply line as close to the dishwasher 
as possible.
Note: Water Hammer Arrestor (meeting
ASSE-1010 standard or equivalent) to be
supplied (by others) in common water supply 
line at service connection.
Volume crated:  
45 cu. ft.
Shipping weight crated:
 
 242 lbs.
Distance between tables:  25-3/8”
utilities
  1  Electrical 
(see box)
  2  Hot Water
3/4” NPT 140°F hot water connection 
(40°F rise booster); 3/4” NPT 110°F hot water
connection; (70°F rise booster)
Flow pressure 20±5 psi
  3  Drain
1-7/8” connection.
SpecificationS
Capacities
Racks per hr.
37
Motor horsepower
Wash
1 Hp
Water consumption
U.S. Gal. per rack
1.7
Temperatures °F
Wash
150
Rinse
180
Time Cycle in Seconds
Wash
55
Drain/Fill/Dwell
12
Rinse
23
Total cycle
90
Straight through
corner configuration
  DH1000 Electrical (40°F Rise) 9 kW
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
  Elec. 
Rated  Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
47
60
60
  230/60/1 
50 
60 
60
  208/60/3
25
35
35
  230/60/3
27
35
35
  DH1000 Electrical (70°F Rise) 12 kW
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
  Elec. 
Rated  Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3 
38 
50 
50
  230/60/3 
41 
50 
50