Champion eucc4 Техническое Руководство

Seite von 6
Upright 24” Conveyor  
Dual Rinse 
Dishwashing Machine
EUCC SERIES
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Booster connections may vary. Contact the Factory.
Standard Voltages
 (Specify choice): 208/60/3, 240/60/3, and 
480/60/3. Available in 3-phase only. For non-standard 3-phase voltages, 
contact the Factory.
Plumbing Notes 
Because of the variation in house-supplied water 
pressure, a water pressure regulating valve (PRV) is needed (water 
PRV is standard). Steam PRV’s may be required for pressure higher 
than 30 psi. The PRVs can either be purchased from Champion or 
obtained locally.
Warning
 Plumbing and electrical connections should be made by 
qualified personnel who will observe all the applicable plumbing, 
sanitary, safety codes and the National Electrical Code.
Note
 Water Hammer Arrestor (meeting ASSE-1010 standard or 
equivalent) to be supplied (by others) in common water supply line  
at service connection.
Venting Notes
  
Fabricated duct size: 3-7/8” x 23-7/8” (outside dimensions)
Utilities EUCC4
  1  Electrical
Contact factory for specific machine electrical requirements  
NOTE: Electric booster connection – contact Factory
  2  Hot Water
3/4” NPT 180°F hot water connection.  
(For machine without built-in booster)
  3  Drain
2” NPT connection
  4  Vents
Load end: 300 CFM 1/4” S.P.
Unload end: 800 CFM 1/4” S.P. With blower-dryer,  
  increase room ventilation by 600 CFM.
Utilities EUCC6
  1  Electrical
Contact factory for specific machine electrical requirements   
NOTE: Electric booster connection – contact Factory
  2  Hot Water
3/4” NPT 180°F hot water connection.  
(For machine without built-in booster)
  3  Drain
2” NPT connection
  4  Vents
Load end: 300 CFM 1/4” S.P.
Unload end: 800 CFM 1/4” S.P. With blower-dryer,  
  increase room ventilation by 600 CFM.
Utilities EUCC8
  1  Electrical
Contact factory for specific machine electrical requirements   
NOTE: Electric booster connection – contact Factory
  2  Hot Water
3/4” NPT 180°F hot water connection.  
(For machine without built-in booster)
  3  Drain
2” NPT connection
  4  Vents
Load end: 300 CFM 1/4” S.P.
Unload end: 800 CFM 1/4” S.P. With blower-dryer,  
  increase room ventilation by 600 CFM.
SPECIFICATIONS
Capacities 
EUCC4  EUCC6  EUCC8
 
 
Dishes per hr. (NSF rated)  10,472 
13,221 
16,495 
 
Conveyor speed (ft./min.)  8.0 
10.1 
12.6 
Motor horsepower
 
Drive 
1/2 Hp 
1/2 Hp 
1/2 Hp 
 
Prewash 30” [762] 
1 Hp 
1 Hp 
1 Hp 
 
Prewash 48” [1219] 
3 Hp  
3 Hp 
3 Hp 
 
Wash 
3 Hp 
3 Hp 
3 Hp 
 
Power Rinse* 
N/A 
3 Hp 
3 Hp  
 
Auxiliary Rinse 
1/5 Hp 
1/5 Hp 
1/5 Hp 
Water consumption
 
Gal. per hr. (max. use) 
115 
113 
141 
Temperatures °F
 
Wash (min.) 
160 
150 
150 
 
Power Rinse (min.)* 
N/A 
160 
160 
 
Auxiliary Rinse (min.) 
165 
165 
165 
 
Final rinse (min.) 
180 
180 
180 
 
Heating
 
Tank heat  
Steam 
Electric 
 
Wash tank 
125 lbs./hr. 
25 kW 
 
Rinse tank * 
100 lbs./hr. 
20 kW 
 
Auxiliary rinse 
50 lbs./hr. 
10 kW
 
Electric booster  
15 
15 
16 
(kW required for 40°F rise) 
 
 
Electric booster  
25 
25 
28 
(kW required for 70°F rise) 
 
 
 Steam booster 
75 
75 
80 
(lbs./hr. required for 40°F rise)   
 
 Steam booster  
125 
125 
135 
(lbs./hr. required for 70°F rise) 
Venting
 
Minimum cfm, load end 
300 
 
Minimum cfm, unload end 
800 
*EUCC4 has no power rinse tank
Shipping weight crated:    150 lbs./ft.[68kg./m.]
Height with doors up:  
 95” 
Height to remove doors:  
 100”