Seite von 6
Volume crated:  
130 cu. ft.
Shipping weight crated:  
865 lbs.
Dimensions shown in inches
Warning: 
Plumbing and electrical connections 
should be made by qualified personnel who will 
observe all the applicable plumbing, sanitary, 
safety codes and the National Electrical Code.
Note: 
Water Hammer Arrestor (meeting ASSE-
1010 standard or equivalent) to be supplied (by 
others) in common water supply line at service 
connection.
Plumbing Notes:
 Because of the variation 
in house-supplied steam and water pressures, 
steam and water pressure regulating valves 
(PRVs) may be needed. (Water PRV is standard on 
machines with booster.) The  
PRVs can either be purchased from  
Champion or obtained locally.
Venting Notes: 
Fabricated duct size:  
3-7/8” x 15-7/8” (Outside dimensions) 
 Machine only
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
162 
200 
200
  240/60/1  
142 
175 
175
  208/60/3  
90 
110 
110
  240/60/3  
80 
100 
100
  480/60/3  
40 
50 
50
  575/60/3  
31 
40 
40
TABle A - MACHINe CoNNeCTIoN
 Machine and steam built-in booster
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
32 
40 
40
  240/60/1  
29 
40 
40 
  208/60/3  
15 
20 
20
  240/60/3  
14 
20 
20
  480/60/3  
15 
15
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
utilities
 
1  Electrical
A  Machine connection (see Table A) 
B  Booster connection (see Table B)
 
2  Hot Water
3/4” NPT 180°F/82°C min. hot water 
connection. (Machine without booster.) 
3/4” NPT 140°F/60°C min. hot water 
connection. (40°F/22°C rise booster) 
3/4” NPT 120°F/49°C min. hot water 
connection. (60°F/34°C rise booster)
3/4” NPT 110°F/49°C min. hot water 
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
 
3  Drain 
1-1/2” NPT machine connection.  
Maximum flow 15 gpm.
 
4  Steam 
A  3/4” NPT machine connection.  
  Flow pressure 15-30 PSI. (Steam coil)
B  3/4” NPT machine connection.  
  Flow pressure 15-30 PSI.  
  (Steam injector)
 
5  Condensate 
(no back pressure)
1/2” NPT machine return to boiler
  6  Vents
A  Load end: 200 CFM @ 1/4” S.P.
B  Unload end: 400 CFM @ 1/4” S.P.  
  (With blower-dryer increase room    
ventilation by 600 CFM.)
64” Two Tank
High-Temperature
Rack Conveyor Dishwashing Machine
Model 64
SPeCIFICATIoNS
Capacity 
Racks per hr. (NSF rated) 
277
Wash tank (US gal.) 
21
Conveyor speed (ft/min.) 
7.7
Motor Horsepower 
Drive  
1/6
Wash 2
Rinse 2
Water Consumption
US Gal. per hr. (max. use) 
124
US Gal. per rack 
.45
Heating
Tank Heat, electric (kW) 
25
Tank heat, steam  
(lbs/hr. required at  
15 PSI flow pressure) 
75
Electric booster (built-in) 
(kw supplied for 40°F rise) 
15
Electric booster (built-in) 
(kW supplied for 70°F rise) 
24
Steam booster (lbs./hr.  
required for 40°F rise) 
120
Steam booster (lbs./hr.  
required for 70°F rise) 
205
Venting
Load end (minimum CFM) 
200
Unload end (minimum CFM) 
400
Standard 20” x 20”  
rack complement
Peg   
2
Flat   
1
TABle B - BooSTeR CoNNeCTIoN
 40°F/22°C Rise – 15kW 
  Electric built-in booster (booster only)
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
42 
50 
50
  240/60/3 
36 
45 
45
  480/60/3  
18 
25 
25
  575/60/3  
15 
20 
20
 70°F/39°C Rise – 24kW 
  Electric built-in booster (booster only)
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
67 
80 
80
  240/60/3 
58 
70 
70
  480/60/3  
29 
35 
35
  575/60/3  
24 
30 
30