Champion uh-100b Техническое Руководство

Seite von 2
CHAMPION
UH100B
25" [635]
4" [102]
15-3/4" [400]
3
2
1
33-3/4" 
[857]
24" [610]
40-1/2" 
[1029]
15-3/4"
[400]
Clearance
2" [51]
1
3
2
CHAMPION
UH100B
25" [635]
4" [102]
15-3/4" [400]
3
2
1
33-3/4" 
[857]
24" [610]
40-1/2" 
[1029]
15-3/4"
[400]
Clearance
2" [51]
1
3
2
Undercounter High Temperature  
Dishwashing Machine  
with Built-in Booster Heater
UH-100B
UH-100B 
U
nderc
OU
nter
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
Dimensions shown in inches and [milimeters] 
Volume crated:
 
 15 cu. ft.  
Shipping weight crated:
 
 215 lbs. 
CHAMPION
UH100B
25" [635]
4" [102]
15-3/4" [400]
3
2
1
33-3/4" 
[857]
24" [610]
40-1/2" 
[1029]
15-3/4"
[400]
Clearance
2" [51]
1
3
2
Front View
Side View
Plan View
Warning 
Plumbing and electrical connections should be made by qualified personnel 
who will observe all the applicable plumbing, sanitary and safety  
codes and the National Electrical Code.
speciFicAtiOns
Capacity
 
Racks per hr. (NSF rated) 
21
Motor horsepower
 
Wash 
1
Water consumption
 
US Gal. per hr. (Max. use) 
38
 
US Gal. per rack 
1.8
Temperatures °F/°C
 
Wash 
150/66
 
Rinse 
180/82
Heating
 
Tank heat, electric (kW) 
2.0
 
Booster, elec., 40°F rise, kW 
6
 
Booster, elec., 70°F rise, kW 
9
Time cycle in seconds
 
Wash 
90
 
Rinse 
26
 
Drain/fill 
25
 
Total cycle 
141
Standard 20” x 20” rack complement
 
Dish 
1
 
Open 
1
*Note: 
Electrical supply 
service must be a 3-wire plus 
ground for connection as 
shown.
115V
115V
208V
L1
L2
N
G
  UH-100 without booster 
  750 Watt tank heat
 
Elec.                       Rated 
 
 
Specs.                       Amps 
  115/60/1                    12
 
Field convertible to accept 3 phase power
UH-100B with 40°F/22°C Rise Booster
Elec. Specs.
Rated 
Amps
Minimum 
Supply Ckt. 
Conductor 
Ampacity
Maximum 
Overcurrent 
Protective 
Device
208/60/1
32
40
40
240/60/1
36
40
40
208/60/3
22
30
30
240/60/3
24
30
30
UH-100B with 70°F/39°C Rise Booster
Elec. Specs.
Rated 
Amps
Minimum 
Supply Ckt. 
Conductor 
Ampacity
Maximum 
Overcurrent 
Protective 
Device
208/60/1
45
60
60
240/60/1
50
60
60
208/60/3
29
35
35
240/60/3
33
40
40
Utilities
1
Electrical
208-240/60/1; 3 wire plus ground, (See Box). 
208-240/60/3; 4 wire plus ground, (See Box).
2
 Hot Water
1/2” supply; 140°F/60°C Min. hot water connection for 40°F/22°C rise booster; 
110°F/43°C Min. hot water connection for 70°F/39°C rise booster. Incoming supply 
pressure must maintain a Flow pressure 20-22 PSI (Pressure reducing valve, PRV, 
supplied by customer or may be purchased unmounted from Champion).  
Machine equipped with 3/4” [19] hose connector.
3
 Pumped Drain
5/8” [15.9] I.D. flexible reinforced hose, 6 ft. [1829] long.  
Max. drain flow 15 US gpm. [12.5 imp gal] Max. drain height 3 ft. [914]