Champion pp-3 Benutzerhandbuch

Seite von 67
C O N T R O L   P A N E L S  
 
Parameter 
Mnemonic 
Description 
Table 1 
Default 
Value  
(Celsius) 
Table 2 Default 
Value 
(Fahrenheit) 
Units 
P 1 
Input table 
2 1 0  
 
P 2 
Low scale range of sensors 
0
 º
c 0
 º
Degrees 
P 3 
High scale range of sensors 
282
 º
c 540
 º
Degrees 
P 4 
Output 1 control action 
r
eu reu 
 
P 5 
Output 2 function 
1   1  
 
P 6 
Output 2 alarm type 
h . r .   h . r .  
 
P 8 
Alarm 1 standby function 
O f f   O f f  
 
P11 
Auto-ranging display 
O f f   O f f  
 
P1 2 
Filter sensor values 
n  
 
 
P 2 2  
Output 3 function 
1 1 
 
P 2 3  
Output 3 alarm type 
h . r .   h . r .  
 
P 2 5  
Alarm 2 standby function 
O f f   O f f  
 
P 3 3  
Access to op.5 mode 
5 5   5 5  
 
P 3 5  
Access to cnf mode 
4 1 5   4 1 5  
 
P 3 6  
Access to I .cl mode 
4 1 5   4 1 5  
 
Configuration Mode Parameter Table 
Loading Celsius or Fahrenheit Tables 
The controller contains two default parameter tables. Table 1 is used for Celsius operation, 
and Table 2 is used for Fahrenheit.  
To load one of the default tables, enter the configuration mode (See instructions listed in the 
Configuration Mode – cnf section listed above). When cnf is displayed, press both the UP 
and DOWN buttons simultaneously. The display will show l . f .  Press the UP or DOWN 
buttons to display l . 1  for table 1 (Celsius), or l . 2  for table 2 (Fahrenheit).  
Press the TEMP key to enter in your selection. The display will show l . . This indicates 
that the loading procedure has been initiated and after approximately 1 second, the loading 
will be finished and the display will revert back to cnf. 
Exit the supervisor mode when done. 
NOTE:
 See Supervisor Mode section on how to exit. 
17