Champion pp-3 Benutzerhandbuch
C O N T R O L P A N E L S
Step Soap Quantity
This setting allows soap quantity control for the step.
Setting name: S T E P X S O A P Q U A N T I T Y
Allowed values: M I N , I N T , M A X
Default value: M I N
Allowed values: M I N , I N T , M A X
Default value: M I N
System States
There are a few states of operation in the controller.
¾ Power Up State
¾ Off State
¾ Wash State
¾ Wash State
¾ Hold / Clean State
Power up State
This state is active on power-up, and also after a Dry Fire (when no water is present in wash
tank).
tank).
A lamp test is performed on the initial power up, all LED’s are lit up for 5 seconds.
Following this test, the software number and revision are displayed. These are useful for
troubleshooting purposes when several versions exist in the field. The first line shows the
software number
Following this test, the software number and revision are displayed. These are useful for
troubleshooting purposes when several versions exist in the field. The first line shows the
software number
(
3 4 1
)
and the second line shows the revision number
(
1 . 5 1
)
.
In this state, all outputs are turned off, and the 1
st
line of the display continually scrolls
F I L L W A S H T A N K W I T H H O T W A T E R
, and the current water temperature (or
empty tank temperature) on the 2
nd
line. All LED’s are off, except the currently selected
language, if selected.
The following counters are reset in this mode:
¾ Total wash time with current soap load (linked to Change Water state)
¾ Total soap injection time for both soap pumps
Once the tank has been filled with water, press the STOP key to enter the OFF state.
From the POWER UP state, the cycle programming and low-level programming menus are
accessible with the proper key sequence.
accessible with the proper key sequence.
31