Champion uh-170b Техническое Руководство

Seite von 2
Undercounter High Temperature  
Dishwashing Machine  
with Built-in Booster Heater
UH-170B
UH-170B 
U
nderco
U
nter
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
Dimensions shown in inches and [milimeters] 
Warning:
Plumbing and electrical connections should be made by qualified personnel 
who will observe all the applicable plumbing, sanitary and safety  
codes and the National Electrical Code.
Note:
Electrical supply 
service must be a 3-wire 
ground for connection 
shown.
Field convertible to accept 3 phase power
Volume crated:
 
 15 cu. ft.  
Shipping weight crated:
 
 215 lbs. 
CHAMPION 
UH170B 
2" [51]
1
2
3
40-1/2"
[1029]
14-3/4"
[375]
Clearance
33-3/4"
[857]
24" [610] 
15-3/4" [400]
4" [102]
25" [635]
2
3
CHAMPION 
UH170B 
2" [51]
1
2
3
40-1/2"
[1029]
14-3/4"
[375]
Clearance
33-3/4"
[857]
24" [610] 
15-3/4" [400]
4" [102]
25" [635]
2
3
CHAMPION 
UH170B 
2" [51]
1
2
3
40-1/2"
[1029]
14-3/4"
[375]
Clearance
33-3/4"
[857]
24" [610] 
15-3/4" [400]
4" [102]
25" [635]
2
3
SPecIFIcatIonS
Capacities
 
Cycle time (seconds) 
90
 
Racks per hr. (NSF) 
30
Motor horsepower
 
Wash 
1
Water consumption
 
U.S. Gal. per hr. (Max. use)  
28.2
 
U.S. Gal. per rack  
.9
Temperatures °F 
 
Wash 
150 
 
Rinse 
180 
Heating
 
Tank heat, electric, kW 
2.0
 
Electric booster  
(kW) required for 40°F rise) 
6
 
Electric booster 
 
(kW) required for 70°F rise) 
9
Time Cycle in Seconds
 
Wash 
70
 
Rinse 
15
 
Total cycle 
90
Standard 20” x 20” Rack Complement
 
Dish 
1
 
Open 
1
 UH-170 without booster
750 watt tank heat
 
Elec.                    Rated 
 
 
Specs.                    Amps 
  115/60/1                  12
115V
115V
208V
L1
L2
N
G
Utilities
1
Electrical
208-240/60/1; 3 wire plus ground, (See Box). 
208-240/60/3; 4 wire plus ground, (See Box).
2
Hot Water
1/2” supply; 140°F Min. hot water connection for 40°F rise booster; 110°F Min. 
hot water connection for 70°F rise booster. Incoming supply pressure must 
maintain a Flow pressure 20-22 PSI (Pressure reducing valve, PRV, supplied by 
customer or may be purchased unmounted from Champion).  
Machine equipped with 3/4” hose connector.
3
Pumped Drain
5/8” I.D. flexible reinforced hose, 6 ft. long.   
Max. drain flow 15 US gpm. 
Max. drain height 3 ft. 
UH-170B with 40°F/22°C Rise Booster
Elec. Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/1
32
40
40
240/60/1
36
40
40
208/60/3
22
30
30
240/60/3
24
30
30
UH-170B with 70°F/39°C Rise Booster
Elec. Specs.
Rated
Amps
Minimum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/1
45
60
60
240/60/1
50
60
60
208/60/3
29
35
35
240/60/3
33
40
40
Side View
Front View
Plan View